Resistência em fadiga cíclica de instrumentos reciprocantes fabricados com ligas de niquel-titânio submetidas a diferentes tratamentos térmicos

Objectives: This study aimed to evaluate and compare the resistance in cyclic fatigue of three types of single file reciprocating systems: WaveOne Gold Primary (25 / 0.07), WA1 file (25 / 0.07) and X1 Blue (25 / 0.06), made of nickel-titanium alloys with different surface thermal treatments, and...