Medição e avaliação da exposição à radiação não ionizante em ambientes internos
Given the rapid rise of telecommunication services and the perspectives of a highly connected society, monitoring the levels of Non-Ionizing Radiation (NIR) that the general population may be exposed to and comparing them with the limits defined in the current norms is essential. Indoor environme...
Na minha lista:
Autor principal: | |
---|---|
Outros Autores: | |
Formato: | Dissertação |
Idioma: | pt_BR |
Publicado em: |
Universidade Federal do Rio Grande do Norte
|
Assuntos: | |
Endereço do item: | https://repositorio.ufrn.br/handle/123456789/57151 |
Tags: |
Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
|
id |
ri-123456789-57151 |
---|---|
record_format |
dspace |
institution |
Repositório Institucional |
collection |
RI - UFRN |
language |
pt_BR |
topic |
Radiação não-ionizante RNI Campo elétrico Medidas em shoppings Medidas em residências CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA |
spellingShingle |
Radiação não-ionizante RNI Campo elétrico Medidas em shoppings Medidas em residências CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA Silva, Júlia da Luz Andrade Medição e avaliação da exposição à radiação não ionizante em ambientes internos |
description |
Given the rapid rise of telecommunication services and the perspectives of a highly
connected society, monitoring the levels of Non-Ionizing Radiation (NIR) that the general
population may be exposed to and comparing them with the limits defined in the current
norms is essential. Indoor environments, such as homes and shopping malls, are places
that meet the interests of measurements, mainly due to the presence of different NIR
sources and the location of these sources about end users. This work presents NIR
measurements in a shopping center and residences in Natal, RN, Brazil. At shopping,
a set of six measurement points was proposed, following two criteria: places with a large
flow of people and the presence of one or more Distributed Antenna System (DAS),
co-located or not with Wi-Fi access points. The results are presented and discussed in
terms of distance from the DAS (conditions: near and far) and flow density of people
in the mall (scenarios: low and high number of people). The highest mean and highest
peak electric fields measured were 1.96 and 3.26 V/m, corresponding respectively to 5%
and 8% of the limits defined by the International Commission on Non-Ionizing Radiation
Protection (ICNIRP) and Agency National Telecommunications Agency (ANATEL). In
the homes, measurements were taken at 40 Wi-Fi access points in usual use situations
and operating at 2.4 and 5 GHz. The results are discussed about connectivity situations,
brand, and equipment use time. The highest exposure level was 4.66 V/m (7.64% of the
legal limit), verified for the network operating at 2.4 GHz. Furthermore, the influence of
the brand and model of the equipment on the measured levels of the average electric field
was noted. Finally, measurements were carried out in 51 microwave ovens, of which only
one exceeded 50 W/m² (the limit determined in current regulations). This radiation leak
was caused by the presence of rust that compromised the structure of the oven door. Two
types of repairs were performed on the oven: using epoxy putty to fill the opening in the
door (Repair 1) and the replacement of the external surface of the oven (Repair 2).Only
Repair 2 effectively solved the problem, generating a measurement with an average of
0.1841 W/m² and a peak of 0.4222 W/m² after the repair. As for the other 50 microwave
ovens, the power density results were presented relating to factors such as the position
of the worst measured point, brand, time of use, and state of conservation of the device.
Given the results, it was possible to note the influence of the factors of time of use and
state of conservation of the oven on the measured average power density. |
author2 |
Sousa Júnior, Vicente Ângelo de |
author_facet |
Sousa Júnior, Vicente Ângelo de Silva, Júlia da Luz Andrade |
format |
masterThesis |
author |
Silva, Júlia da Luz Andrade |
author_sort |
Silva, Júlia da Luz Andrade |
title |
Medição e avaliação da exposição à radiação não ionizante em ambientes internos |
title_short |
Medição e avaliação da exposição à radiação não ionizante em ambientes internos |
title_full |
Medição e avaliação da exposição à radiação não ionizante em ambientes internos |
title_fullStr |
Medição e avaliação da exposição à radiação não ionizante em ambientes internos |
title_full_unstemmed |
Medição e avaliação da exposição à radiação não ionizante em ambientes internos |
title_sort |
medição e avaliação da exposição à radiação não ionizante em ambientes internos |
publisher |
Universidade Federal do Rio Grande do Norte |
publishDate |
2024 |
url |
https://repositorio.ufrn.br/handle/123456789/57151 |
work_keys_str_mv |
AT silvajuliadaluzandrade medicaoeavaliacaodaexposicaoaradiacaonaoionizanteemambientesinternos |
_version_ |
1790056006746636288 |
spelling |
ri-123456789-571512024-01-03T19:44:26Z Medição e avaliação da exposição à radiação não ionizante em ambientes internos Silva, Júlia da Luz Andrade Sousa Júnior, Vicente Ângelo de https://orcid.org/0000-0003-0980-039X http://lattes.cnpq.br/5296758749431721 https://orcid.org/0000-0003-2859-6136 http://lattes.cnpq.br/6358312955522220 Campos, Antônio Luiz Pereira de Siqueira http://lattes.cnpq.br/1982228057731254 Andrade, Humberto Dionisio de Radiação não-ionizante RNI Campo elétrico Medidas em shoppings Medidas em residências CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA Given the rapid rise of telecommunication services and the perspectives of a highly connected society, monitoring the levels of Non-Ionizing Radiation (NIR) that the general population may be exposed to and comparing them with the limits defined in the current norms is essential. Indoor environments, such as homes and shopping malls, are places that meet the interests of measurements, mainly due to the presence of different NIR sources and the location of these sources about end users. This work presents NIR measurements in a shopping center and residences in Natal, RN, Brazil. At shopping, a set of six measurement points was proposed, following two criteria: places with a large flow of people and the presence of one or more Distributed Antenna System (DAS), co-located or not with Wi-Fi access points. The results are presented and discussed in terms of distance from the DAS (conditions: near and far) and flow density of people in the mall (scenarios: low and high number of people). The highest mean and highest peak electric fields measured were 1.96 and 3.26 V/m, corresponding respectively to 5% and 8% of the limits defined by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) and Agency National Telecommunications Agency (ANATEL). In the homes, measurements were taken at 40 Wi-Fi access points in usual use situations and operating at 2.4 and 5 GHz. The results are discussed about connectivity situations, brand, and equipment use time. The highest exposure level was 4.66 V/m (7.64% of the legal limit), verified for the network operating at 2.4 GHz. Furthermore, the influence of the brand and model of the equipment on the measured levels of the average electric field was noted. Finally, measurements were carried out in 51 microwave ovens, of which only one exceeded 50 W/m² (the limit determined in current regulations). This radiation leak was caused by the presence of rust that compromised the structure of the oven door. Two types of repairs were performed on the oven: using epoxy putty to fill the opening in the door (Repair 1) and the replacement of the external surface of the oven (Repair 2).Only Repair 2 effectively solved the problem, generating a measurement with an average of 0.1841 W/m² and a peak of 0.4222 W/m² after the repair. As for the other 50 microwave ovens, the power density results were presented relating to factors such as the position of the worst measured point, brand, time of use, and state of conservation of the device. Given the results, it was possible to note the influence of the factors of time of use and state of conservation of the oven on the measured average power density. Conselho Nacional de Desenvolvimento Científico e Tecnológico - CNPq Tendo em vista a rápida ascensão dos serviços de telecomunicação e as perspectivas de um sociedade extremamente conectada, é fundamental monitorar os níveis de Radiação Não-Ionizante (RNI) que a população em geral pode estar exposta e compará-los com os limites definidos nas normas vigentes. Ambientes internos (indoor), como residências e shoppings, são locais que atendem aos interesses das medições, devido principalmente a presença de diferentes fontes de RNI e a localização dessas fontes em relação aos usuários finais. Este trabalho apresenta medições de RNI em um shopping center e em residências em Natal, RN, Brasil. No shopping, foi proposto um conjunto de seis pontos de medição, seguindo dois critérios: locais com grande fluxo de pessoas e presença de um ou mais Distributed Antenna System (DAS), co-localizados ou não com pontos de acesso Wi-Fi. Os resultados são apresentados e discutidos em termos de distância do DAS (condições: perto e longe) e densidade de fluxo de pessoas no shopping (cenários: baixo e alto número de pessoas). A maior média e maior pico de campo elétrico medidos foram 1,96 e 3,26 V/m, correspondendo respectivamente a 5% e 8% dos limites definidos pela Comissão Internacional de Proteção contra Radiações Não Ionizantes (ICNIRP) e Agência Nacional de Telecomunicações (ANATEL). Nas residências, foram realizadas medições em 40 pontos de acesso Wi-Fi em situações usuais de utilização e operando em 2,4 e 5 GHz. Os resultados são discutidos em relação a situações de conectividade, marca e tempo de uso do equipamento. O maior nível de exposição foi de 4,66 V/m (7,64% do limite legal), verificado para a rede operando em 2,4 GHz. Além disso, foi notado influência do fator marca e modelo do equipamento nos níveis medidos de campo elétrico médio. Finalmente, foram realizadas medições em 51 fornos de micro-ondas, dos quais somente um excedeu 50 W/m² (limite determinado nas normas vigentes). Esse vazamento de radiação foi provocado pela presença de ferrugem que comprometeu a estrutura da porta do forno. Dois tipos de reparos foram realizados no forno: uso de massa epóxi para preencher a abertura na porta (Reparo 1) e troca da superfície externa do forno (Reparo 2). Somente o Reparo 2 solucionou o problema efetivamente, gerando um medição com média de 0,1841 W/m² e pico de 0,4222 W/m² depois do conserto. Quanto aos 50 demais fornos de micro-ondas, foram apresentados os resultados de densidade de potência relacionando com fatores como posição do pior ponto medido, marca, tempo de uso e estado de conservação do aparelho. Diante dos resultados, foi possível notar a influência dos fatores tempo de uso e estado de conservação do forno na densidade de potência média medida. 2024-01-03T19:43:45Z 2024-01-03T19:43:45Z 2023-09-22 masterThesis SILVA, Júlia da Luz Andrade. Medição e avaliação da exposição à radiação não ionizante em ambientes internos. Orientador: Dr. Vicente Ângelo de Sousa Júnior. 2023. 49f. Dissertação (Mestrado em Engenharia Elétrica e de Computação) - Centro de Tecnologia, Universidade Federal do Rio Grande do Norte, Natal, 2023. https://repositorio.ufrn.br/handle/123456789/57151 pt_BR Acesso Aberto application/pdf Universidade Federal do Rio Grande do Norte Brasil UFRN PROGRAMA DE PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA E DE COMPUTAÇÃO |