Avaliação da validade e confiabilidade do teste de AVD-Glittre em pacientes com insuficiência cardíaca

Introduction: Due to exercise intolerance and consequent limitations in activities of daily living (ADLs), which are common clinical features in patients with heart failure, the assessment of functional capacity should be widely employed to measure treatment response, monitor disease progression, an...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Principais autores: Oliveira, Gabriella Lima de, Souza, Gerson Fonseca de
Formato: bachelorThesis
Idioma:pt_BR
Publicado em: Universidade Federal do Rio Grande do Norte
Assuntos:
Endereço do item:https://repositorio.ufrn.br/handle/123456789/55944
Tags: Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
id ri-123456789-55944
record_format dspace
institution Repositório Institucional
collection RI - UFRN
language pt_BR
topic Insuficiência cardíaca
Teste de exercício
Confiabilidade e validade
Heart failure
Exercise test
Reliability and validity
CNPQ::CIENCIAS DA SAUDE
spellingShingle Insuficiência cardíaca
Teste de exercício
Confiabilidade e validade
Heart failure
Exercise test
Reliability and validity
CNPQ::CIENCIAS DA SAUDE
Oliveira, Gabriella Lima de
Souza, Gerson Fonseca de
Avaliação da validade e confiabilidade do teste de AVD-Glittre em pacientes com insuficiência cardíaca
description Introduction: Due to exercise intolerance and consequent limitations in activities of daily living (ADLs), which are common clinical features in patients with heart failure, the assessment of functional capacity should be widely employed to measure treatment response, monitor disease progression, and predict prognosis in these patients. Although there is consensus that instruments used to measure health outcomes should have good measurement properties, the Glittre Activities of Daily Living (ADL-Glittre) test has not yet had its properties studied in patients with heart failure. Objective: To assess the validity and reliability of the ADL-Glittre test in patients with heart failure with reduced ejection fraction (HFrEF). Methods: Retrospective cross-sectional study, including adult patients aged 18-80 years, of both biological sexes, diagnosed with HFrEF, who underwent initial assessment in the cardiac rehabilitation program at CORE/HUOL: 6-minute walk test (6MWT), ADL-Glittre test, handgrip dynamometry, and Minnesota Living with Heart Failure Questionnaire (MLHFQ). Results: 75 medical records were evaluated, with a final sample of 22 patients. The time of the ADL-Glittre test (T-Glittre) showed a moderate correlation with the 6-minute walk distance (r = - 0,51, p = 0,025) and with the physical dimension score of MLHFQ (r = 0,67, p = 0,009). No significant correlation was found between T-Glittre and ejection fraction, as well as with handgrip strength measurement. Test-retest reliability for T-Glittre showed a moderate intraclass correlation coefficient (ICC = 0,7). Conclusion: The data suggest that the ADL-Glittre test is a valid and reliable tool for assessing the functional capacity of patients with HFrEF.
author2 Souza, Gerson Fonseca de
author_facet Souza, Gerson Fonseca de
Oliveira, Gabriella Lima de
Souza, Gerson Fonseca de
format bachelorThesis
author Oliveira, Gabriella Lima de
Souza, Gerson Fonseca de
author_sort Oliveira, Gabriella Lima de
title Avaliação da validade e confiabilidade do teste de AVD-Glittre em pacientes com insuficiência cardíaca
title_short Avaliação da validade e confiabilidade do teste de AVD-Glittre em pacientes com insuficiência cardíaca
title_full Avaliação da validade e confiabilidade do teste de AVD-Glittre em pacientes com insuficiência cardíaca
title_fullStr Avaliação da validade e confiabilidade do teste de AVD-Glittre em pacientes com insuficiência cardíaca
title_full_unstemmed Avaliação da validade e confiabilidade do teste de AVD-Glittre em pacientes com insuficiência cardíaca
title_sort avaliação da validade e confiabilidade do teste de avd-glittre em pacientes com insuficiência cardíaca
publisher Universidade Federal do Rio Grande do Norte
publishDate 2023
url https://repositorio.ufrn.br/handle/123456789/55944
work_keys_str_mv AT oliveiragabriellalimade avaliacaodavalidadeeconfiabilidadedotestedeavdglittreempacientescominsuficienciacardiaca
AT souzagersonfonsecade avaliacaodavalidadeeconfiabilidadedotestedeavdglittreempacientescominsuficienciacardiaca
AT oliveiragabriellalimade evaluationofthevalidityandreliabilityoftheadlglittretestinpatientswithheartfailure
AT souzagersonfonsecade evaluationofthevalidityandreliabilityoftheadlglittretestinpatientswithheartfailure
_version_ 1785623043620470784
spelling ri-123456789-559442023-12-14T20:41:00Z Avaliação da validade e confiabilidade do teste de AVD-Glittre em pacientes com insuficiência cardíaca Evaluation of the validity and reliability of the ADL-Glittre test in patients with heart failure Oliveira, Gabriella Lima de Souza, Gerson Fonseca de Souza, Gerson Fonseca de Nogueira, Ivan Daniel Bezerra York, Beatriz Souza de Albuquerque Cacique New Insuficiência cardíaca Teste de exercício Confiabilidade e validade Heart failure Exercise test Reliability and validity CNPQ::CIENCIAS DA SAUDE Introduction: Due to exercise intolerance and consequent limitations in activities of daily living (ADLs), which are common clinical features in patients with heart failure, the assessment of functional capacity should be widely employed to measure treatment response, monitor disease progression, and predict prognosis in these patients. Although there is consensus that instruments used to measure health outcomes should have good measurement properties, the Glittre Activities of Daily Living (ADL-Glittre) test has not yet had its properties studied in patients with heart failure. Objective: To assess the validity and reliability of the ADL-Glittre test in patients with heart failure with reduced ejection fraction (HFrEF). Methods: Retrospective cross-sectional study, including adult patients aged 18-80 years, of both biological sexes, diagnosed with HFrEF, who underwent initial assessment in the cardiac rehabilitation program at CORE/HUOL: 6-minute walk test (6MWT), ADL-Glittre test, handgrip dynamometry, and Minnesota Living with Heart Failure Questionnaire (MLHFQ). Results: 75 medical records were evaluated, with a final sample of 22 patients. The time of the ADL-Glittre test (T-Glittre) showed a moderate correlation with the 6-minute walk distance (r = - 0,51, p = 0,025) and with the physical dimension score of MLHFQ (r = 0,67, p = 0,009). No significant correlation was found between T-Glittre and ejection fraction, as well as with handgrip strength measurement. Test-retest reliability for T-Glittre showed a moderate intraclass correlation coefficient (ICC = 0,7). Conclusion: The data suggest that the ADL-Glittre test is a valid and reliable tool for assessing the functional capacity of patients with HFrEF. Introdução: Devido a intolerância ao exercício e, consequentemente, a limitação das atividades de vida diária (AVDs) serem características clínicas comuns nos pacientes com insuficiência cardíaca, a avaliação da capacidade funcional deveria ser amplamente utilizada para medir resposta ao tratamento, acompanhamento da evolução da doença e prognóstico nestes pacientes. Embora haja consenso de que os instrumentos utilizados para medida de desfechos em saúde devem ter boas propriedades de medida, o teste de AVD-Glittre ainda não teve essas propriedades estudadas em pacientes com insuficiência cardíaca. Objetivo: Avaliar a validade e confiabilidade do teste de AVD-Glittre em pacientes com insuficiência cardíaca com fração de ejeção reduzida (ICFER). Metodologia: Estudo transversal retrospectivo, incluindo pacientes adultos, com idade entre 18-80 anos, de ambos os sexos biológicos, diagnosticados com ICFER, que foram submetidos à avaliação inicial do programa de reabilitação cardíaca do CORE/HUOL: Teste de caminhada de seis minutos (TC6), teste de AVD-Glittre, dinamometria de preensão palmar e Minnesota Living with Heart Failure Questionnaire (MLHFQ). Resultados: 75 prontuários avaliados, amostra final composta de 22 pacientes. O tempo do teste de AVD-Glittre (T-Glittre) apresentou moderada correlação com a distância caminhada em 6 minutos (r = - 0,51, p = 0,025) e com o escore da dimensão física do MLHFQ (r = 0,67, p = 0,009). Não foi encontrada correlação significante entre o T-Glittre e a FEVE, bem como com a medida de força preensão palmar. A confiabilidade teste-reteste para o T-Glittre mostrou valor de coeficiente de correlação intraclasse moderado (CCI = 0,7). Conclusão: Os dados sugerem que o teste de AVD-Glittre é uma ferramenta válida e confiável para avaliar a capacidade funcional dos pacientes com ICFER. 2023-12-14T20:41:00Z 2023-12-14T20:41:00Z 2023-12-04 bachelorThesis OLIVEIRA, Gabriella Lima de. Avaliação da validade e confiabilidade do teste de AVD-Glittre em pacientes com insuficiência cardíaca. Orientador: Gerson Fonseca de Souza. 2023. 34 f. Trabalho de Conclusão de Curso (Graduação em Fisioterapia) - Departamento de Fisioterapia, Universidade Federal do Rio Grande do Norte, Natal, 2023. https://repositorio.ufrn.br/handle/123456789/55944 pt_BR Attribution-NonCommercial-NoDerivs 3.0 Brazil http://creativecommons.org/licenses/by-nc-nd/3.0/br/ application/pdf Universidade Federal do Rio Grande do Norte Brasil UFRN