Estabilidade da glicose "in vitro": comparação entre 4 tipos de tubo de coleta de sangue

Introduction: blood glucose determination must be accurate and precise. However, “in vitro” glycolysis may influence the result of this determination. Thus, the ideal is to choose the appropriate collection tube that make it possible to minimize falsely diminished results. Objective: to evaluate the...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Autor principal: Schunck, Bruna Silvino
Outros Autores: Ururahy, Marcela Abbott Galvão
Formato: bachelorThesis
Idioma:pt_BR
Publicado em: Universidade Federal do Rio Grande do Norte
Assuntos:
Endereço do item:https://repositorio.ufrn.br/handle/123456789/50708
Tags: Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
id ri-123456789-50708
record_format dspace
institution Repositório Institucional
collection RI - UFRN
language pt_BR
topic ativador de coágulo
clot activator
citrato de sódio
sodium citrate
gel separador
separating gel
tubo de coleta
collection tube
fluoreto de sódio
sodium fluoride
glicólise
glycolysis
spellingShingle ativador de coágulo
clot activator
citrato de sódio
sodium citrate
gel separador
separating gel
tubo de coleta
collection tube
fluoreto de sódio
sodium fluoride
glicólise
glycolysis
Schunck, Bruna Silvino
Estabilidade da glicose "in vitro": comparação entre 4 tipos de tubo de coleta de sangue
description Introduction: blood glucose determination must be accurate and precise. However, “in vitro” glycolysis may influence the result of this determination. Thus, the ideal is to choose the appropriate collection tube that make it possible to minimize falsely diminished results. Objective: to evaluate the stability of glucose concentration in blood samples collected in tubes with sodium fluoride/EDTA, sodium citrate, clot activator, and clot activator/separator gel over 10h after collection. Material and methods: Blood samples were collected by venipuncture from 36 individuals, after an 8-hour fast. Samples were collected under vacuum, in 4 types of collection tubes and centrifuged within 30 minutes after collection. Glucose dosage was performed every 1 hour, for 10 hours. Results: the samples collected with tubes containing clot activator/without separator gel and tubes with sodium citrate, showed a decay of 10.1% and 7.9%, respectively, 10 hours after collection. No significant decay in glycemia was observed for the other evaluated tubes. Discussion: studies including collection tubes containing sodium citrate in association with other anticoagulants, such as sodium fluoride, EDTA, oxalate, could contribute to assess the best type of collection tube to determinate glycemia. Conclusions: Results suggest that tubes containing clot activator/separating gel and sodium fluoride/EDTA are able to maintain glucose stability “in vitro”, once the sample is centrifuged within 30 minutes of collection.
author2 Ururahy, Marcela Abbott Galvão
author_facet Ururahy, Marcela Abbott Galvão
Schunck, Bruna Silvino
format bachelorThesis
author Schunck, Bruna Silvino
author_sort Schunck, Bruna Silvino
title Estabilidade da glicose "in vitro": comparação entre 4 tipos de tubo de coleta de sangue
title_short Estabilidade da glicose "in vitro": comparação entre 4 tipos de tubo de coleta de sangue
title_full Estabilidade da glicose "in vitro": comparação entre 4 tipos de tubo de coleta de sangue
title_fullStr Estabilidade da glicose "in vitro": comparação entre 4 tipos de tubo de coleta de sangue
title_full_unstemmed Estabilidade da glicose "in vitro": comparação entre 4 tipos de tubo de coleta de sangue
title_sort estabilidade da glicose "in vitro": comparação entre 4 tipos de tubo de coleta de sangue
publisher Universidade Federal do Rio Grande do Norte
publishDate 2022
url https://repositorio.ufrn.br/handle/123456789/50708
work_keys_str_mv AT schunckbrunasilvino estabilidadedaglicoseinvitrocomparacaoentre4tiposdetubodecoletadesangue
AT schunckbrunasilvino invitroglucosestabilitycomparisonbetween4typesofbloodcollectiontube
_version_ 1773963695696642048
spelling ri-123456789-507082022-12-27T12:00:50Z Estabilidade da glicose "in vitro": comparação entre 4 tipos de tubo de coleta de sangue "In vitro" glucose stability: comparison between 4 types of blood collection tube Schunck, Bruna Silvino Ururahy, Marcela Abbott Galvão http://lattes.cnpq.br/8016222352823817 Souza, Karla Simone Costa de http://lattes.cnpq.br/2262063068881600 Duarte, Victor Hugo Rezende http://lattes.cnpq.br/5892971598537293 Pinheiro, Marília Gabriella de Oliveira ativador de coágulo clot activator citrato de sódio sodium citrate gel separador separating gel tubo de coleta collection tube fluoreto de sódio sodium fluoride glicólise glycolysis Introduction: blood glucose determination must be accurate and precise. However, “in vitro” glycolysis may influence the result of this determination. Thus, the ideal is to choose the appropriate collection tube that make it possible to minimize falsely diminished results. Objective: to evaluate the stability of glucose concentration in blood samples collected in tubes with sodium fluoride/EDTA, sodium citrate, clot activator, and clot activator/separator gel over 10h after collection. Material and methods: Blood samples were collected by venipuncture from 36 individuals, after an 8-hour fast. Samples were collected under vacuum, in 4 types of collection tubes and centrifuged within 30 minutes after collection. Glucose dosage was performed every 1 hour, for 10 hours. Results: the samples collected with tubes containing clot activator/without separator gel and tubes with sodium citrate, showed a decay of 10.1% and 7.9%, respectively, 10 hours after collection. No significant decay in glycemia was observed for the other evaluated tubes. Discussion: studies including collection tubes containing sodium citrate in association with other anticoagulants, such as sodium fluoride, EDTA, oxalate, could contribute to assess the best type of collection tube to determinate glycemia. Conclusions: Results suggest that tubes containing clot activator/separating gel and sodium fluoride/EDTA are able to maintain glucose stability “in vitro”, once the sample is centrifuged within 30 minutes of collection. Introdução: a determinação da glicemia deve ser exata e precisa. Porém, a glicólise “in vitro” pode alterar o resultado da dosagem. Assim, o ideal é escolher o tubo de coleta adequado que possibilite minimizar resultados falsamente diminuídos. Objetivo: avaliar a estabilidade da concentração de glicose em amostras de sangue coletadas em tubos com fluoreto de sódio/EDTA, citrato de sódio, ativador de coágulo e ativador de coágulo/gel separador ao longo de 10h após a coleta. Material e métodos: foi realizada coleta de sangue, por punção venosa, de 36 indivíduos, após jejum de 8 horas. As amostras foram coletadas à vácuo, em 4 tipos de tubos de coleta e centrifugadas em até 30 minutos após a coleta. A glicemia foi determinada a cada 1 hora, durante 10 horas. Resultados: as amostras coletadas com tubos contendo ativador de coágulo/sem gel separador e tubos com citrato de sódio, apresentaram um decaimento de 10,1% e 7,9%, respectivamente, 10 horas após coleta. Não foi observado um decaimento significativo da glicemia nos demais tubos avaliados. Discussão: estudos incluindo tubos de coleta contendo citrato de sódio em associação com outros anticoagulantes, como fluoreto de sódio, EDTA e oxalato, podem contribuir para definir o melhor tipo de tubo de coleta de sangue para a determinação da glicemia. Conclusões: os resultados sugerem que os tubos contendo ativador de coágulo/gel separador e com fluoreto de sódio/EDTA conseguem manter a estabilidade da glicose “in vitro”, desde que a amostra seja centrifugada dentro de 30 minutos após a coleta. 2022-12-27T12:00:50Z 2022-12-27T12:00:50Z 2022-12-02 bachelorThesis SCHUNCK, Bruna Silvino. Estabilidade da glicose "in vitro": comparação entre 4 tipos de tubo de coleta de sangue. 2022. 20 f. Trabalho de Conclusão de Curso (Graduação em Farmácia) - Departamento de Análises Clínicas e Toxicológicas, Universidade Federal do Rio Grande do Norte, Natal, 2022. https://repositorio.ufrn.br/handle/123456789/50708 pt_BR application/pdf Universidade Federal do Rio Grande do Norte Brasil UFRN Farmácia Análises clínicas e toxicológicas