Avaliação da acurácia dos modelos dentários digitais obtidos para cirurgia ortognática

The objective of this experimental study was to evaluate the accuracy of digital models generated by two scanning techniques (intraoral scanner - Itero 5d Element® - and desktop scanner -Straumann ®) of an experimental model of the upper arch (Nacional Ossos ®) made of polyurethane and the plaste...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Autor principal: Santos, Victor Diniz Borborema dos
Outros Autores: Silva, José Sandro Pereira da
Formato: doctoralThesis
Idioma:pt_BR
Publicado em: Universidade Federal do Rio Grande do Norte
Assuntos:
Endereço do item:https://repositorio.ufrn.br/handle/123456789/47063
Tags: Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
id ri-123456789-47063
record_format dspace
institution Repositório Institucional
collection RI - UFRN
language pt_BR
topic Cirurgia ortognática
Modelos dentários
Escaneamento intraoral
spellingShingle Cirurgia ortognática
Modelos dentários
Escaneamento intraoral
Santos, Victor Diniz Borborema dos
Avaliação da acurácia dos modelos dentários digitais obtidos para cirurgia ortognática
description The objective of this experimental study was to evaluate the accuracy of digital models generated by two scanning techniques (intraoral scanner - Itero 5d Element® - and desktop scanner -Straumann ®) of an experimental model of the upper arch (Nacional Ossos ®) made of polyurethane and the plaster model obtained from this arch. Points A – 3mm above element 17; B – 3mm above element 14; C – 3mm above element 24; D – 3mm above element 27; E – mesiobuccal cusp of element 16; F - most incisal point of contact between elements 11 and 21; G - Mesiobuccal cusp of element 26 were used as a reference for the measurements performed. The measurements were performed in a surgical simulation software (Geomagic ®) and analyzed for the validity and precision of the scanning techniques used in all groups (1 to 5). Group 1 corresponds to the gold standard group; 2 to the scanning group with intraoral scanner of the polyurethane model; 3 to the desktop scan of the model; 4 to intraoral scanner scanning of the plaster model; and 5 to the desktop scan of the plaster model. In the validation analysis, all techniques showed to be valid compared to the control group, except the FG measure, which showed statistically significant differences (p<0.05) between groups 1 and 2. Precision was assessed using the intraclass correlation(ICC) index, and all techniques were highly accurate with an ICC close to 1. Thus, it is concluded that the intraoral scanner and the bench scanner used in this study were reliable compared to the control group and that the two scanner models used presented themselves with high precision.
author2 Silva, José Sandro Pereira da
author_facet Silva, José Sandro Pereira da
Santos, Victor Diniz Borborema dos
format doctoralThesis
author Santos, Victor Diniz Borborema dos
author_sort Santos, Victor Diniz Borborema dos
title Avaliação da acurácia dos modelos dentários digitais obtidos para cirurgia ortognática
title_short Avaliação da acurácia dos modelos dentários digitais obtidos para cirurgia ortognática
title_full Avaliação da acurácia dos modelos dentários digitais obtidos para cirurgia ortognática
title_fullStr Avaliação da acurácia dos modelos dentários digitais obtidos para cirurgia ortognática
title_full_unstemmed Avaliação da acurácia dos modelos dentários digitais obtidos para cirurgia ortognática
title_sort avaliação da acurácia dos modelos dentários digitais obtidos para cirurgia ortognática
publisher Universidade Federal do Rio Grande do Norte
publishDate 2022
url https://repositorio.ufrn.br/handle/123456789/47063
work_keys_str_mv AT santosvictordinizborboremados avaliacaodaacuraciadosmodelosdentariosdigitaisobtidosparacirurgiaortognatica
_version_ 1773962539715002368
spelling ri-123456789-470632022-04-27T19:52:39Z Avaliação da acurácia dos modelos dentários digitais obtidos para cirurgia ortognática Santos, Victor Diniz Borborema dos Silva, José Sandro Pereira da http://lattes.cnpq.br/2748340374251866 https://orcid.org/0000-0001-9774-7175 http://lattes.cnpq.br/7625795408417124 Morais, Hecio Henrique Araújo de https://orcid.org/0000-0002-6450-1483 http://lattes.cnpq.br/9568109998934778 Noleto Júnior, José Wilson Sales, Marcelo Augusto de Oliveira http://lattes.cnpq.br/9070705545715779 Dantas, Wagner Ranier Maciel https://orcid.org/ 0000-0002-4904-187X http://lattes.cnpq.br/4012589060182732 Cirurgia ortognática Modelos dentários Escaneamento intraoral The objective of this experimental study was to evaluate the accuracy of digital models generated by two scanning techniques (intraoral scanner - Itero 5d Element® - and desktop scanner -Straumann ®) of an experimental model of the upper arch (Nacional Ossos ®) made of polyurethane and the plaster model obtained from this arch. Points A – 3mm above element 17; B – 3mm above element 14; C – 3mm above element 24; D – 3mm above element 27; E – mesiobuccal cusp of element 16; F - most incisal point of contact between elements 11 and 21; G - Mesiobuccal cusp of element 26 were used as a reference for the measurements performed. The measurements were performed in a surgical simulation software (Geomagic ®) and analyzed for the validity and precision of the scanning techniques used in all groups (1 to 5). Group 1 corresponds to the gold standard group; 2 to the scanning group with intraoral scanner of the polyurethane model; 3 to the desktop scan of the model; 4 to intraoral scanner scanning of the plaster model; and 5 to the desktop scan of the plaster model. In the validation analysis, all techniques showed to be valid compared to the control group, except the FG measure, which showed statistically significant differences (p<0.05) between groups 1 and 2. Precision was assessed using the intraclass correlation(ICC) index, and all techniques were highly accurate with an ICC close to 1. Thus, it is concluded that the intraoral scanner and the bench scanner used in this study were reliable compared to the control group and that the two scanner models used presented themselves with high precision. O objetivo deste estudo laboratorial foi avaliar a acurácia dos modelos digitais obtidos por duas técnicas de escaneamento (escâner intraoral - Itero 5d Element® - e escâner de bancada -Straumann ®) de um modelo experimental (Nacional Ossos ®) da arcada superior confeccionada em poliuretano e do modelo de gesso obtido desta arcada. Os pontos A – 3mm acima do elemento 17; B – 3mm acima do elemento 14; C – 3mm acima do elemento 24; D – 3mm acima do elemento 27; E – cúspide mesiovestibular do elemento 16; F - ponto de contato mais incisal entre os elementos 11 e 21; G - Cúspide mesiovestibular do elemento 26 foram utilizados como referência para as medidas realizadas. As medidas foram realizadas em um software (Geomagic®) de simulação cirúrgica e analisadas quanto a validade e precisão das técnicas de escaneamento utilizadas em todos os grupos (1 a 5). O grupo 1 corresponde ao grupo padrão-ouro; o 2 ao grupo do escaneamento com escâner intraoral do modelo de poliuretano; o 3 ao escaneamento de bancada do modelo; o 4 ao escaneamento com escâner intraoral do modelo de gesso; e 5 ao escaneamento de bancada do modelo de gesso. Na análise da validação, todas as técnicas apresentaram-se válidas quando comparadas ao grupo controle com exceção da medida FG que apresentou diferenças estatisticamente significativas (p<0,05) entre os grupos 1 e 2. A precisão foi avaliada através do índice de correlação intraclasse (CCI) e todas as técnicas apresentaram-se altamente precisas com (CCI) próximo de 1. Desta forma, conclui-se que o escâner intraoral e o escâner de bancada utilizados neste estudo foram confiáveis quando comparados ao grupo controle e que os dois modelos de escâner utilizados se apresentaram com alta precisão. 2022-04-27T19:51:52Z 2022-04-27T19:51:52Z 2022-02-25 doctoralThesis SANTOS, Victor Diniz Borborema dos. Avaliação da acurácia dos modelos dentários digitais obtidos para cirurgia ortognática. 2022. 35f. Tese (Doutorado em Ciências Odontológicas) - Centro de Ciências da Saúde, Universidade Federal do Rio Grande do Norte, Natal, 2022. https://repositorio.ufrn.br/handle/123456789/47063 pt_BR Acesso Aberto application/pdf Universidade Federal do Rio Grande do Norte Brasil UFRN PROGRAMA DE PÓS-GRADUAÇÃO EM CIÊNCIAS ODONTOLÓGICAS