Application of nitriding and duplex treatment on steel drills-HSS
The present study aims to evaluate the application of plasma nitriding (at temperatures of 450° and 500°C) and duplex treatment (conventional nitriding followed by TiN deposition, using the cathodic cage deposition technique). Samples were characterized by Vickers Microhardness Test, Scanning Electr...
Na minha lista:
Principais autores: | , , , , , |
---|---|
Formato: | article |
Idioma: | English |
Publicado em: |
JMEST
|
Assuntos: | |
Endereço do item: | https://repositorio.ufrn.br/handle/123456789/45516 |
Tags: |
Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
|
id |
ri-123456789-45516 |
---|---|
record_format |
dspace |
spelling |
ri-123456789-455162021-12-21T13:53:53Z Application of nitriding and duplex treatment on steel drills-HSS Feitor, Michelle Cequeira Serra, Petteson Linniker Carvalho Sousa, Rômulo Ribeiro Magalhães de Barros Neto, João Rodrigues de Libório, Maxwell Santana Costa, Thércio Henrique de Carvalho Plasma nitriding Duplex treatment Drills High-speed steel (HSS) Drilling The present study aims to evaluate the application of plasma nitriding (at temperatures of 450° and 500°C) and duplex treatment (conventional nitriding followed by TiN deposition, using the cathodic cage deposition technique). Samples were characterized by Vickers Microhardness Test, Scanning Electron Microscopy-SEM, and Energy Dispersion Spectroscopy-EDS. Drill performance was evaluated after machining SAE1045 steel specimens, using flank wear and hole diameter measurements. The performance test pointed to the viability of the treatment at 450°C, whose treated drill had a longer life than in the untreated drill, in addition to meeting the dimensional quality in all holes. In contrast, the other tools, nitrided at 500°C and submitted to the duplex treatment, they presented performance below the expected, not showing viability for application in these conditions. Additionally, it was observed the existence of a thermal gradient formed during the treatment 2021-12-21T13:17:52Z 2021-12-21T13:17:52Z 2020-04 article SERRA, P.L.C.; Sousa, R.R.M.; BARROS NETO, J.R.; LIBORIO, M.S.; FEITOR, M.C.; COSTA, T.H.C.; FURTADO, A.S.. Application of nitriding and duplex treatment on steel drills-HSS. Journal of Multidisciplinary Engineering Science and Technology (JMEST), v. 7, n. 4, p. 11699-11708, abr. 2020. Disponível em: http://www.jmest.org/wp-content/uploads/JMESTN42353330.pdf. Acesso em 14 abr. 2021. 2458-9403 https://repositorio.ufrn.br/handle/123456789/45516 en application/pdf JMEST |
institution |
Repositório Institucional |
collection |
RI - UFRN |
language |
English |
topic |
Plasma nitriding Duplex treatment Drills High-speed steel (HSS) Drilling |
spellingShingle |
Plasma nitriding Duplex treatment Drills High-speed steel (HSS) Drilling Feitor, Michelle Cequeira Serra, Petteson Linniker Carvalho Sousa, Rômulo Ribeiro Magalhães de Barros Neto, João Rodrigues de Libório, Maxwell Santana Costa, Thércio Henrique de Carvalho Application of nitriding and duplex treatment on steel drills-HSS |
description |
The present study aims to evaluate the application of plasma nitriding (at temperatures of 450° and 500°C) and duplex treatment (conventional nitriding followed by TiN deposition, using the cathodic cage deposition technique). Samples were characterized by Vickers Microhardness Test, Scanning Electron Microscopy-SEM, and Energy Dispersion Spectroscopy-EDS. Drill performance was evaluated after machining SAE1045 steel
specimens, using flank wear and hole diameter measurements. The performance test pointed to the viability of the treatment at 450°C, whose treated drill had a longer life than in the untreated drill, in addition to meeting the dimensional quality in all holes. In contrast, the other tools, nitrided at 500°C and submitted to the duplex treatment, they presented performance below the expected, not showing viability for application in these conditions. Additionally, it was observed the existence of a thermal gradient formed during the treatment |
format |
article |
author |
Feitor, Michelle Cequeira Serra, Petteson Linniker Carvalho Sousa, Rômulo Ribeiro Magalhães de Barros Neto, João Rodrigues de Libório, Maxwell Santana Costa, Thércio Henrique de Carvalho |
author_facet |
Feitor, Michelle Cequeira Serra, Petteson Linniker Carvalho Sousa, Rômulo Ribeiro Magalhães de Barros Neto, João Rodrigues de Libório, Maxwell Santana Costa, Thércio Henrique de Carvalho |
author_sort |
Feitor, Michelle Cequeira |
title |
Application of nitriding and duplex treatment on steel drills-HSS |
title_short |
Application of nitriding and duplex treatment on steel drills-HSS |
title_full |
Application of nitriding and duplex treatment on steel drills-HSS |
title_fullStr |
Application of nitriding and duplex treatment on steel drills-HSS |
title_full_unstemmed |
Application of nitriding and duplex treatment on steel drills-HSS |
title_sort |
application of nitriding and duplex treatment on steel drills-hss |
publisher |
JMEST |
publishDate |
2021 |
url |
https://repositorio.ufrn.br/handle/123456789/45516 |
work_keys_str_mv |
AT feitormichellecequeira applicationofnitridingandduplextreatmentonsteeldrillshss AT serrapettesonlinnikercarvalho applicationofnitridingandduplextreatmentonsteeldrillshss AT sousaromuloribeiromagalhaesde applicationofnitridingandduplextreatmentonsteeldrillshss AT barrosnetojoaorodriguesde applicationofnitridingandduplextreatmentonsteeldrillshss AT liboriomaxwellsantana applicationofnitridingandduplextreatmentonsteeldrillshss AT costatherciohenriquedecarvalho applicationofnitridingandduplextreatmentonsteeldrillshss |
_version_ |
1773962295702978560 |