Multi-elemental analysis of produced water by synchrotron radiation total reflection X-ray fluorescence
he synchrotron radiation total reflection X-ray fluorescence (SRTXRF) technique was used for the analysis of heavy metals in produced watersamples from oil field in Rio Grande do Norte, in order to determine potential sources of pollution. Since the inorganic components in producedwater generally re...
Na minha lista:
Principais autores: | , , , , , , |
---|---|
Formato: | article |
Idioma: | English |
Publicado em: |
Elsevier
|
Assuntos: | |
Endereço do item: | https://repositorio.ufrn.br/handle/123456789/45171 |
Tags: |
Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
|
id |
ri-123456789-45171 |
---|---|
record_format |
dspace |
spelling |
ri-123456789-451712021-12-08T13:15:29Z Multi-elemental analysis of produced water by synchrotron radiation total reflection X-ray fluorescence Melo, Marcus Antônio de Freitas Pimentel, Patrícia Mendonça Anjos, Marcelino José dos Melo, Dulce Maria de Araújo Gonçalves Júnior, Lauro de Melo Silva Júnior, Carlos Neco da Lopes, R. T. SRTXRF Produced water Heavy metals he synchrotron radiation total reflection X-ray fluorescence (SRTXRF) technique was used for the analysis of heavy metals in produced watersamples from oil field in Rio Grande do Norte, in order to determine potential sources of pollution. Since the inorganic components in producedwater generally resembling sea water, pre-concentration procedures have been applied to increase the concentration of the analyte of interest andto minimize the salt matrix effects. This technique allows us to determine the contents of V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Hg and Pb in 20 producedwater samples. The great majority of the sampling points presented low elemental concentration value. However, in some sample, the Fe, Ni, Cu,Zn and Hg concentration were higher than the established limits by the Brazilian legislation 2021-12-06T14:11:01Z 2021-12-06T14:11:01Z 2008-02-15 article PIMENTEL, P. M.; ANJOS, Marcelino José dos; MELO, Dulce Maria de Araújo; MELO, M. A. F.; GONÇALVES JUNIOR, Lauro de Melo; SILVA, Carlos Neco da; LOPES, R. T. . Multi-elemental analysis of producd water by Synchroton radiation total reflection X-ray fluorescence. Talanta (Oxford), v. 74, p. 1231-1235, 2008. Disponível em: https://www.sciencedirect.com/science/article/pii/S0039914007005851?via%3Dihub Acesso em: 10 ago. 2021. https://doi.org/10.1016/j.talanta.2007.08.028 0039-9140 https://repositorio.ufrn.br/handle/123456789/45171 10.1016/j.talanta.2007.08.028 en Attribution 3.0 Brazil http://creativecommons.org/licenses/by/3.0/br/ application/pdf Elsevier |
institution |
Repositório Institucional |
collection |
RI - UFRN |
language |
English |
topic |
SRTXRF Produced water Heavy metals |
spellingShingle |
SRTXRF Produced water Heavy metals Melo, Marcus Antônio de Freitas Pimentel, Patrícia Mendonça Anjos, Marcelino José dos Melo, Dulce Maria de Araújo Gonçalves Júnior, Lauro de Melo Silva Júnior, Carlos Neco da Lopes, R. T. Multi-elemental analysis of produced water by synchrotron radiation total reflection X-ray fluorescence |
description |
he synchrotron radiation total reflection X-ray fluorescence (SRTXRF) technique was used for the analysis of heavy metals in produced watersamples from oil field in Rio Grande do Norte, in order to determine potential sources of pollution. Since the inorganic components in producedwater generally resembling sea water, pre-concentration procedures have been applied to increase the concentration of the analyte of interest andto minimize the salt matrix effects. This technique allows us to determine the contents of V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Hg and Pb in 20 producedwater samples. The great majority of the sampling points presented low elemental concentration value. However, in some sample, the Fe, Ni, Cu,Zn and Hg concentration were higher than the established limits by the Brazilian legislation |
format |
article |
author |
Melo, Marcus Antônio de Freitas Pimentel, Patrícia Mendonça Anjos, Marcelino José dos Melo, Dulce Maria de Araújo Gonçalves Júnior, Lauro de Melo Silva Júnior, Carlos Neco da Lopes, R. T. |
author_facet |
Melo, Marcus Antônio de Freitas Pimentel, Patrícia Mendonça Anjos, Marcelino José dos Melo, Dulce Maria de Araújo Gonçalves Júnior, Lauro de Melo Silva Júnior, Carlos Neco da Lopes, R. T. |
author_sort |
Melo, Marcus Antônio de Freitas |
title |
Multi-elemental analysis of produced water by synchrotron radiation total reflection X-ray fluorescence |
title_short |
Multi-elemental analysis of produced water by synchrotron radiation total reflection X-ray fluorescence |
title_full |
Multi-elemental analysis of produced water by synchrotron radiation total reflection X-ray fluorescence |
title_fullStr |
Multi-elemental analysis of produced water by synchrotron radiation total reflection X-ray fluorescence |
title_full_unstemmed |
Multi-elemental analysis of produced water by synchrotron radiation total reflection X-ray fluorescence |
title_sort |
multi-elemental analysis of produced water by synchrotron radiation total reflection x-ray fluorescence |
publisher |
Elsevier |
publishDate |
2021 |
url |
https://repositorio.ufrn.br/handle/123456789/45171 |
work_keys_str_mv |
AT melomarcusantoniodefreitas multielementalanalysisofproducedwaterbysynchrotronradiationtotalreflectionxrayfluorescence AT pimentelpatriciamendonca multielementalanalysisofproducedwaterbysynchrotronradiationtotalreflectionxrayfluorescence AT anjosmarcelinojosedos multielementalanalysisofproducedwaterbysynchrotronradiationtotalreflectionxrayfluorescence AT melodulcemariadearaujo multielementalanalysisofproducedwaterbysynchrotronradiationtotalreflectionxrayfluorescence AT goncalvesjuniorlaurodemelo multielementalanalysisofproducedwaterbysynchrotronradiationtotalreflectionxrayfluorescence AT silvajuniorcarlosnecoda multielementalanalysisofproducedwaterbysynchrotronradiationtotalreflectionxrayfluorescence AT lopesrt multielementalanalysisofproducedwaterbysynchrotronradiationtotalreflectionxrayfluorescence |
_version_ |
1773966311331725312 |