Influência de sistemas de escaneamento na precisão de contatos oclusais e interproximais de coroas cerâmicas obtidas por tecnologia cad/cam

CAD/CAM systems are today an important ally to the Dentist and the Prosthodontics Technician in the manufacture of ceramic crowns with greater accuracy and efficiency. With the passing of the years this equipment has been obtaining an increasing adhesion on the part of the Dental professionals. The...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Autor principal: Albuquerque Neto, Carlos Morais de
Outros Autores: Barbosa, Gustavo Augusto Seabra
Formato: bachelorThesis
Idioma:pt_BR
Publicado em: Universidade Federal do Rio Grande do Norte
Assuntos:
Endereço do item:https://repositorio.ufrn.br/handle/123456789/39000
Tags: Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
id ri-123456789-39000
record_format dspace
institution Repositório Institucional
collection RI - UFRN
language pt_BR
topic Sistema CAD/CAM
Precisão dos contatos oclusais
Precisão dos contatos interproximais
CEREC BlueCAM
CEREC Apollo DI
spellingShingle Sistema CAD/CAM
Precisão dos contatos oclusais
Precisão dos contatos interproximais
CEREC BlueCAM
CEREC Apollo DI
Albuquerque Neto, Carlos Morais de
Influência de sistemas de escaneamento na precisão de contatos oclusais e interproximais de coroas cerâmicas obtidas por tecnologia cad/cam
description CAD/CAM systems are today an important ally to the Dentist and the Prosthodontics Technician in the manufacture of ceramic crowns with greater accuracy and efficiency. With the passing of the years this equipment has been obtaining an increasing adhesion on the part of the Dental professionals. The Purpose of this study was to evaluate the influence of different CAD/CAM systems on the occlusal and interproximal contacts accuracy of ceramic unit crowns. This is a comparative In Vitro study involving 2 groups of 10 crowns of lithium disilicate manufactured from 2 types of scanning, the CEREC BlueCam system and CEREC Apollo DI system. Evaluations of occlusal and interproximal were performed by a previously single trained examiner. For the occlusal contacts accuracy, CEREC BlueCam system presented 90% of the crowns manufactured in lithium disilicate according to the parameter considered “clinically excellent” compared to 30% of the crowns manufactured from CEREC Apollo DI system for the same parameter. Standing this second system with 70% of its manufactured crowns according to the parameter considered “clinically good” to the occlusal contacts accuracy. Concerning the interproximal contacts accuracy there were no significant differences, with CEREC BlueCam system presenting 100% of the manufactured crowns according to the parameter considered “clinically excellent” compared to 80% of the crowns manufactured by CEREC Apollo DI system for the same parameter. Within the limitations of the study, it can be concluded that, for the aspects of occlusal contacts accuracy and interproximal contacts accuracy, CEREC BlueCam system was superior than CEREC Apollo DI system.
author2 Barbosa, Gustavo Augusto Seabra
author_facet Barbosa, Gustavo Augusto Seabra
Albuquerque Neto, Carlos Morais de
format bachelorThesis
author Albuquerque Neto, Carlos Morais de
author_sort Albuquerque Neto, Carlos Morais de
title Influência de sistemas de escaneamento na precisão de contatos oclusais e interproximais de coroas cerâmicas obtidas por tecnologia cad/cam
title_short Influência de sistemas de escaneamento na precisão de contatos oclusais e interproximais de coroas cerâmicas obtidas por tecnologia cad/cam
title_full Influência de sistemas de escaneamento na precisão de contatos oclusais e interproximais de coroas cerâmicas obtidas por tecnologia cad/cam
title_fullStr Influência de sistemas de escaneamento na precisão de contatos oclusais e interproximais de coroas cerâmicas obtidas por tecnologia cad/cam
title_full_unstemmed Influência de sistemas de escaneamento na precisão de contatos oclusais e interproximais de coroas cerâmicas obtidas por tecnologia cad/cam
title_sort influência de sistemas de escaneamento na precisão de contatos oclusais e interproximais de coroas cerâmicas obtidas por tecnologia cad/cam
publisher Universidade Federal do Rio Grande do Norte
publishDate 2017
url https://repositorio.ufrn.br/handle/123456789/39000
work_keys_str_mv AT albuquerquenetocarlosmoraisde influenciadesistemasdeescaneamentonaprecisaodecontatosoclusaiseinterproximaisdecoroasceramicasobtidasportecnologiacadcam
_version_ 1773965000683028480
spelling ri-123456789-390002023-05-03T13:38:16Z Influência de sistemas de escaneamento na precisão de contatos oclusais e interproximais de coroas cerâmicas obtidas por tecnologia cad/cam Albuquerque Neto, Carlos Morais de Barbosa, Gustavo Augusto Seabra BARBOSA, Gustavo Augusto Seabra ALMEIDA, Érika Oliveira de RESENDE, Camila Maria Bastos Machado de Sistema CAD/CAM Precisão dos contatos oclusais Precisão dos contatos interproximais CEREC BlueCAM CEREC Apollo DI CAD/CAM systems are today an important ally to the Dentist and the Prosthodontics Technician in the manufacture of ceramic crowns with greater accuracy and efficiency. With the passing of the years this equipment has been obtaining an increasing adhesion on the part of the Dental professionals. The Purpose of this study was to evaluate the influence of different CAD/CAM systems on the occlusal and interproximal contacts accuracy of ceramic unit crowns. This is a comparative In Vitro study involving 2 groups of 10 crowns of lithium disilicate manufactured from 2 types of scanning, the CEREC BlueCam system and CEREC Apollo DI system. Evaluations of occlusal and interproximal were performed by a previously single trained examiner. For the occlusal contacts accuracy, CEREC BlueCam system presented 90% of the crowns manufactured in lithium disilicate according to the parameter considered “clinically excellent” compared to 30% of the crowns manufactured from CEREC Apollo DI system for the same parameter. Standing this second system with 70% of its manufactured crowns according to the parameter considered “clinically good” to the occlusal contacts accuracy. Concerning the interproximal contacts accuracy there were no significant differences, with CEREC BlueCam system presenting 100% of the manufactured crowns according to the parameter considered “clinically excellent” compared to 80% of the crowns manufactured by CEREC Apollo DI system for the same parameter. Within the limitations of the study, it can be concluded that, for the aspects of occlusal contacts accuracy and interproximal contacts accuracy, CEREC BlueCam system was superior than CEREC Apollo DI system. Os sistemas CAD/CAM são hoje um importante aliado ao Cirurgião Dentista e o Técnico em Prótese Dentária na confecção de coroas em cerâmica com maior precisão e eficácia. Com o passar dos anos estes equipamentos vem obtendo uma crescente adesão por parte dos profissionais da área odontológica. O Objetivo desse estudo foi avaliar a influência de diferentes sistemas de CAD/CAM na precisão dos contatos oclusais e interproximais de coroas unitárias cerâmicas. Trata-se de um estudo do tipo In vitro, comparativo envolvendo 2 grupos de 10 coroas de dissilicato de lítio fabricadas a partir de 2 tipos de escaneamento, o sistema CEREC BlueCam e o sistema CEREC Apollo DI. As avaliações dos contatos oclusais e interproximais foram realizadas por um único examinador previamente treinado. Para a precisão dos contatos oclusais, o sistema CEREC BlueCam apresentou 90% das coroas fabricadas em dissilicato de lítio atendendo o parâmetro considerado “clinicamente excelente” frente a 30% das coroas fabricadas a partir do sistema CEREC Apollo DI para o mesmo parâmetro. Ficando esse segundo sistema com 70% de suas coroas fabricadas atendendo ao parâmetro de “clinicamente bom” para a precisão dos contatos oclusais. Já com relação a precisão dos contatos interproximais não houve diferenças, com o sistema CEREC BlueCam apresentando 100% das coroas fabricadas atendendo ao parâmetro de “clinicamente excelente” frente a 80% das coroas fabricadas pelo sistema CEREC Apollo DI para o mesmo parâmetro. Dentro das limitações do estudo, pode-se concluir que, para os aspectos de precisão dos contatos oclusais e precisão dos contatos interproximais, o sistema CEREC BlueCam mostrou-se superior quando comparado ao sistema CEREC Apollo DI. 2017-10-02T13:09:53Z 2021-09-27T14:01:52Z 2017-10-02T13:09:53Z 2021-09-27T14:01:52Z 2017-06-19 bachelorThesis 2013040704 ALBUQUERQUE NETO, Carlos Morais de. Influência de sistemas de escaneamento na precisão de contatos oclusais e interproximais de coroas cerâmicas obtidas por tecnologia cad/cam. 2017. Monografia (Graduação) - Departamento de Odontologia, Universidade Federal do Rio Grande do Norte, Natal, 2017. https://repositorio.ufrn.br/handle/123456789/39000 pt_BR openAccess application/pdf Universidade Federal do Rio Grande do Norte Brasil UFRN Odontologia