Parameters for dimensional Inspection of orifice plates and roughness of the straight stretches of the tubing

According to the Technical Regulation of Measurement of Petroleum and Natural Gas (approved in 2000 by ANP – the Petroleum National Agency of Brazil), the systems of measurement of natural gas should use ultrasonic flow meters, turbines and, especially, the orifice plates, which represent the most e...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Principais autores: Medeiros, Alberto Kennedy de Almeida, Lima, Jeffersson Fernandes de, Medeiros, Gilson Gomes de, Silva Junior, Nivaldo Ferreira da, Felipe, Raimundo Nonato B., Felipe, Renata Carla Tavares dos Santos
Formato: article
Idioma:English
Publicado em: Instituto de Tecnologia do Paraná - Tecpar
Assuntos:
Endereço do item:https://repositorio.ufrn.br/handle/123456789/33224
Tags: Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
Descrição
Resumo:According to the Technical Regulation of Measurement of Petroleum and Natural Gas (approved in 2000 by ANP – the Petroleum National Agency of Brazil), the systems of measurement of natural gas should use ultrasonic flow meters, turbines and, especially, the orifice plates, which represent the most expressive base of the flow systems, being used in the fiscal and operational measurements. This work aims to evaluate the parameters that should be accounted for during the dimensional inspection of orifice plate and roughness of the straight stretches of the tubing used for measurement of natural gas, with the objective of guiding the responsible professionals for the measurement of volumes of natural gas by orifice plate, as well as the professionals of calibration laboratories. In this work, minimum specifications are recommended, irrespective of the pressure tapping or orifice type, in agreement with the norms ISO, AGA and the ANP regulations. The influence of these specifications on the parameters used in the calculation of the volumetric flow is also analyzed