Traveling wave-based transmission line earth fault distance protection

This paper proposes a one-terminal traveling wave (TW)-based transmission line earth fault distance protection function. It only needs the detection of the first incident modal earth fault-induced TWs, so that, the challenging detection of wavefronts reflected from the fault point is not required. B...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Principais autores: França, Rafael Lucas da Silva, Silva Júnior, Francisco C., Honorato, Tiago R., Ribeiro, João Paulo .G., Costa, Flávio Bezerra, Lopes, Felipe. V., Strunz, Kai
Formato: article
Idioma:English
Publicado em: Institute of Electrical and Electronics Engineers (IEEE)
Assuntos:
Endereço do item:https://repositorio.ufrn.br/jspui/handle/123456789/29801
Tags: Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
id ri-123456789-29801
record_format dspace
spelling ri-123456789-298012020-08-16T07:12:22Z Traveling wave-based transmission line earth fault distance protection França, Rafael Lucas da Silva Silva Júnior, Francisco C. Honorato, Tiago R. Ribeiro, João Paulo .G. Costa, Flávio Bezerra Lopes, Felipe. V. Strunz, Kai Transmission line protection Traveling waves One-terminal protection Earth faults Protective relay This paper proposes a one-terminal traveling wave (TW)-based transmission line earth fault distance protection function. It only needs the detection of the first incident modal earth fault-induced TWs, so that, the challenging detection of wavefronts reflected from the fault point is not required. Both the sampling frequency effect and inaccuracies on the wave propagation velocity are considered in order to define the distance protection zone. Simulated fault records were played back in an actual relay, allowing the comparison between a commercially existing time-domain distance protection element and the proposed one. The proposed function is more accurate and significantly reduces transmission line 2020-08-11T19:23:56Z 2020-08-11T19:23:56Z 2020-04-02 article FRANCA, Rafael Lucas; SILVA JUNIOR, Francisco; HONORATO, Tiago; RIBEIRO, Joao Paulo; COSTA, Flavio; LOPES, Felipe; STRUNZ, Kai. Traveling Wave-Based Transmission Line Earth Fault Distance Protection. Ieee Transactions On Power Delivery, [s.l.], p. 1-1, 2020. Disponível em: https://ieeexplore.ieee.org/document/9055162/authors#authors. Acesso em: 08 ago 2020. http://dx.doi.org/10.1109/tpwrd.2020.2984585 1937-4208 https://repositorio.ufrn.br/jspui/handle/123456789/29801 10.1109/TPWRD.2020.2984585 en Attribution 3.0 Brazil http://creativecommons.org/licenses/by/3.0/br/ application/pdf Institute of Electrical and Electronics Engineers (IEEE)
institution Repositório Institucional
collection RI - UFRN
language English
topic Transmission line protection
Traveling waves
One-terminal protection
Earth faults
Protective relay
spellingShingle Transmission line protection
Traveling waves
One-terminal protection
Earth faults
Protective relay
França, Rafael Lucas da Silva
Silva Júnior, Francisco C.
Honorato, Tiago R.
Ribeiro, João Paulo .G.
Costa, Flávio Bezerra
Lopes, Felipe. V.
Strunz, Kai
Traveling wave-based transmission line earth fault distance protection
description This paper proposes a one-terminal traveling wave (TW)-based transmission line earth fault distance protection function. It only needs the detection of the first incident modal earth fault-induced TWs, so that, the challenging detection of wavefronts reflected from the fault point is not required. Both the sampling frequency effect and inaccuracies on the wave propagation velocity are considered in order to define the distance protection zone. Simulated fault records were played back in an actual relay, allowing the comparison between a commercially existing time-domain distance protection element and the proposed one. The proposed function is more accurate and significantly reduces transmission line
format article
author França, Rafael Lucas da Silva
Silva Júnior, Francisco C.
Honorato, Tiago R.
Ribeiro, João Paulo .G.
Costa, Flávio Bezerra
Lopes, Felipe. V.
Strunz, Kai
author_facet França, Rafael Lucas da Silva
Silva Júnior, Francisco C.
Honorato, Tiago R.
Ribeiro, João Paulo .G.
Costa, Flávio Bezerra
Lopes, Felipe. V.
Strunz, Kai
author_sort França, Rafael Lucas da Silva
title Traveling wave-based transmission line earth fault distance protection
title_short Traveling wave-based transmission line earth fault distance protection
title_full Traveling wave-based transmission line earth fault distance protection
title_fullStr Traveling wave-based transmission line earth fault distance protection
title_full_unstemmed Traveling wave-based transmission line earth fault distance protection
title_sort traveling wave-based transmission line earth fault distance protection
publisher Institute of Electrical and Electronics Engineers (IEEE)
publishDate 2020
url https://repositorio.ufrn.br/jspui/handle/123456789/29801
work_keys_str_mv AT francarafaellucasdasilva travelingwavebasedtransmissionlineearthfaultdistanceprotection
AT silvajuniorfranciscoc travelingwavebasedtransmissionlineearthfaultdistanceprotection
AT honoratotiagor travelingwavebasedtransmissionlineearthfaultdistanceprotection
AT ribeirojoaopaulog travelingwavebasedtransmissionlineearthfaultdistanceprotection
AT costaflaviobezerra travelingwavebasedtransmissionlineearthfaultdistanceprotection
AT lopesfelipev travelingwavebasedtransmissionlineearthfaultdistanceprotection
AT strunzkai travelingwavebasedtransmissionlineearthfaultdistanceprotection
_version_ 1773963032640094208