Wide frequency range magnetoimpedance in tri-layered thin NiFe/Ag/NiFe films: experiment and numerical calculation

Given that the magnetoinductive effect (MI), skin effect and ferromagnetic resonance influence magnetic permeability behavior at different frequency ranges, the description of the magnetoimpedance effect over a wide range of frequency becomes a difficult task. To that end, we perform an experimental...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Principais autores: Corrêa, Marcio Assolin, Bohn, Felipe, Escobar, Vivian Montardo, Marques, M. S., Viegas, A. D. C., Schelp, L. F., Sommer, R. L.
Formato: article
Idioma:English
Publicado em: AIP Publishing
Assuntos:
Endereço do item:https://repositorio.ufrn.br/jspui/handle/123456789/29513
Tags: Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
id ri-123456789-29513
record_format dspace
spelling ri-123456789-295132020-07-12T07:48:02Z Wide frequency range magnetoimpedance in tri-layered thin NiFe/Ag/NiFe films: experiment and numerical calculation Corrêa, Marcio Assolin Bohn, Felipe Escobar, Vivian Montardo Marques, M. S. Viegas, A. D. C. Schelp, L. F. Sommer, R. L. Magnetoinductive effect Magnetoimpedance effect Given that the magnetoinductive effect (MI), skin effect and ferromagnetic resonance influence magnetic permeability behavior at different frequency ranges, the description of the magnetoimpedance effect over a wide range of frequency becomes a difficult task. To that end, we perform an experimental investigation of the magnetoimpedance effect in a tri-layered thin film over a wide frequency range. We compare the experimental results for a tri-layered thin film with numerical calculus performed using an approach that considers a magnetic transverse susceptibility model for planar systems and an appropriate magnetoimpedance model for a tri-layered system together. The results show remarkably good agreement between numerical calculus and experimental measurements. Thus, we discuss the experimental results in terms of different mechanisms that govern the MI changes observed in distinct frequency ranges and provide experimental support to confirm the validity of the theoretical approach 2020-07-09T02:26:04Z 2020-07-09T02:26:04Z 2011-11-08 article CORRÊA, M. A.; BOHN, F.; ESCOBAR, V. M.; MARQUES, M. S.; VIEGAS, A. D. C.; SCHELP, L. F.; SOMMER, R. L.. Wide frequency range magnetoimpedance in tri-layered thin NiFe/Ag/NiFe films: experiment and numerical calculation. : Experiment and numerical calculation. Journal of Applied Physics, [s.l.], v. 110, n. 9, p. 093914, nov. 2011. Disponível em: http://dx.doi.org/10.1063/1.3658262. Acesso em: 24 maio 2020. https://doi.org/10.1063/1.3658262 0021-8979 https://repositorio.ufrn.br/jspui/handle/123456789/29513 10.1063/1.3658262 en application/pdf AIP Publishing
institution Repositório Institucional
collection RI - UFRN
language English
topic Magnetoinductive effect
Magnetoimpedance effect
spellingShingle Magnetoinductive effect
Magnetoimpedance effect
Corrêa, Marcio Assolin
Bohn, Felipe
Escobar, Vivian Montardo
Marques, M. S.
Viegas, A. D. C.
Schelp, L. F.
Sommer, R. L.
Wide frequency range magnetoimpedance in tri-layered thin NiFe/Ag/NiFe films: experiment and numerical calculation
description Given that the magnetoinductive effect (MI), skin effect and ferromagnetic resonance influence magnetic permeability behavior at different frequency ranges, the description of the magnetoimpedance effect over a wide range of frequency becomes a difficult task. To that end, we perform an experimental investigation of the magnetoimpedance effect in a tri-layered thin film over a wide frequency range. We compare the experimental results for a tri-layered thin film with numerical calculus performed using an approach that considers a magnetic transverse susceptibility model for planar systems and an appropriate magnetoimpedance model for a tri-layered system together. The results show remarkably good agreement between numerical calculus and experimental measurements. Thus, we discuss the experimental results in terms of different mechanisms that govern the MI changes observed in distinct frequency ranges and provide experimental support to confirm the validity of the theoretical approach
format article
author Corrêa, Marcio Assolin
Bohn, Felipe
Escobar, Vivian Montardo
Marques, M. S.
Viegas, A. D. C.
Schelp, L. F.
Sommer, R. L.
author_facet Corrêa, Marcio Assolin
Bohn, Felipe
Escobar, Vivian Montardo
Marques, M. S.
Viegas, A. D. C.
Schelp, L. F.
Sommer, R. L.
author_sort Corrêa, Marcio Assolin
title Wide frequency range magnetoimpedance in tri-layered thin NiFe/Ag/NiFe films: experiment and numerical calculation
title_short Wide frequency range magnetoimpedance in tri-layered thin NiFe/Ag/NiFe films: experiment and numerical calculation
title_full Wide frequency range magnetoimpedance in tri-layered thin NiFe/Ag/NiFe films: experiment and numerical calculation
title_fullStr Wide frequency range magnetoimpedance in tri-layered thin NiFe/Ag/NiFe films: experiment and numerical calculation
title_full_unstemmed Wide frequency range magnetoimpedance in tri-layered thin NiFe/Ag/NiFe films: experiment and numerical calculation
title_sort wide frequency range magnetoimpedance in tri-layered thin nife/ag/nife films: experiment and numerical calculation
publisher AIP Publishing
publishDate 2020
url https://repositorio.ufrn.br/jspui/handle/123456789/29513
work_keys_str_mv AT correamarcioassolin widefrequencyrangemagnetoimpedanceintrilayeredthinnifeagnifefilmsexperimentandnumericalcalculation
AT bohnfelipe widefrequencyrangemagnetoimpedanceintrilayeredthinnifeagnifefilmsexperimentandnumericalcalculation
AT escobarvivianmontardo widefrequencyrangemagnetoimpedanceintrilayeredthinnifeagnifefilmsexperimentandnumericalcalculation
AT marquesms widefrequencyrangemagnetoimpedanceintrilayeredthinnifeagnifefilmsexperimentandnumericalcalculation
AT viegasadc widefrequencyrangemagnetoimpedanceintrilayeredthinnifeagnifefilmsexperimentandnumericalcalculation
AT schelplf widefrequencyrangemagnetoimpedanceintrilayeredthinnifeagnifefilmsexperimentandnumericalcalculation
AT sommerrl widefrequencyrangemagnetoimpedanceintrilayeredthinnifeagnifefilmsexperimentandnumericalcalculation
_version_ 1773962712571707392