Sistema de reconhecimento de imagens para avaliação do movimento toracoabdominal em recém-nascidos

This project has been develop in partnership with Trairí’s Health Science Faculty (FACISA – UFRN ) aiming to optimize the evaluation of thoracoabdominal movements in newborns, after receiving physiotherapeutic respiratory maneuver. However, in newborns, there is no effective method to assess respira...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Principais autores: Oliveira, Heitor Bernardino de, Pereira, Silvana Alves, Vale, Bárbara Emmily Cavalcanti, Nagem, Danilo Alves Pinto
Formato: article
Idioma:pt_BR
Publicado em: Revista Brasileira de Inovação Tecnologica em Saúde
Assuntos:
Endereço do item:https://repositorio.ufrn.br/jspui/handle/123456789/29461
Tags: Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
id ri-123456789-29461
record_format dspace
institution Repositório Institucional
collection RI - UFRN
language pt_BR
topic Reconhecimento de imagem
Cinemática respiratória
Mecânica respiratória
Fotogrametria
Recém-nascido
spellingShingle Reconhecimento de imagem
Cinemática respiratória
Mecânica respiratória
Fotogrametria
Recém-nascido
Oliveira, Heitor Bernardino de
Pereira, Silvana Alves
Vale, Bárbara Emmily Cavalcanti
Nagem, Danilo Alves Pinto
Sistema de reconhecimento de imagens para avaliação do movimento toracoabdominal em recém-nascidos
description This project has been develop in partnership with Trairí’s Health Science Faculty (FACISA – UFRN ) aiming to optimize the evaluation of thoracoabdominal movements in newborns, after receiving physiotherapeutic respiratory maneuver. However, in newborns, there is no effective method to assess respiratory kinematics. The traditional technique for respiratory volume measurement, called plethysmography, is not viable for clinical assessments in neonates. Some papers propose a different solution for this problem; by using lateral pictures of the newborn and processing those images in vector-based software, like CorelDraw or AutoCAD, where the user has to manually add a curve over the thoracoabdominal region to delimitate the wanted areas. On these softwares, each picture has to be individually analyzed, the focus area has to be calculated and converted to cm2, by applying an appropriated scale, which is derived from a standard length value in the image. After compiling all the images, the maximum and minimum point of the respiratory motion is acquired, providing enough data to evaluate the efficiency of the maneuver. Nevertheless, this process is slow and inaccurate, because it relies on user’s proficiency on said softwares. In this context, this project was developed, as a first functional and automated method to determine the thoracoabdominal volume from 2D images of neonates. Developed using MATLAB’s image processing toolboxes, the algorithm is capable of identifying the reference points and demarcating the thorax curvature automatically. This way, the application was able to process and quantify, sequentially, a larger set of images, always using the same standard, determining the maximum and minimum areas of the thorax and the abdomen throughout the entire respiratory motion of newborns, before and after applying the physiotherapeutic respiratory maneuver
format article
author Oliveira, Heitor Bernardino de
Pereira, Silvana Alves
Vale, Bárbara Emmily Cavalcanti
Nagem, Danilo Alves Pinto
author_facet Oliveira, Heitor Bernardino de
Pereira, Silvana Alves
Vale, Bárbara Emmily Cavalcanti
Nagem, Danilo Alves Pinto
author_sort Oliveira, Heitor Bernardino de
title Sistema de reconhecimento de imagens para avaliação do movimento toracoabdominal em recém-nascidos
title_short Sistema de reconhecimento de imagens para avaliação do movimento toracoabdominal em recém-nascidos
title_full Sistema de reconhecimento de imagens para avaliação do movimento toracoabdominal em recém-nascidos
title_fullStr Sistema de reconhecimento de imagens para avaliação do movimento toracoabdominal em recém-nascidos
title_full_unstemmed Sistema de reconhecimento de imagens para avaliação do movimento toracoabdominal em recém-nascidos
title_sort sistema de reconhecimento de imagens para avaliação do movimento toracoabdominal em recém-nascidos
publisher Revista Brasileira de Inovação Tecnologica em Saúde
publishDate 2020
url https://repositorio.ufrn.br/jspui/handle/123456789/29461
work_keys_str_mv AT oliveiraheitorbernardinode sistemadereconhecimentodeimagensparaavaliacaodomovimentotoracoabdominalemrecemnascidos
AT pereirasilvanaalves sistemadereconhecimentodeimagensparaavaliacaodomovimentotoracoabdominalemrecemnascidos
AT valebarbaraemmilycavalcanti sistemadereconhecimentodeimagensparaavaliacaodomovimentotoracoabdominalemrecemnascidos
AT nagemdaniloalvespinto sistemadereconhecimentodeimagensparaavaliacaodomovimentotoracoabdominalemrecemnascidos
_version_ 1773961521574969344
spelling ri-123456789-294612020-07-12T07:49:35Z Sistema de reconhecimento de imagens para avaliação do movimento toracoabdominal em recém-nascidos Oliveira, Heitor Bernardino de Pereira, Silvana Alves Vale, Bárbara Emmily Cavalcanti Nagem, Danilo Alves Pinto Reconhecimento de imagem Cinemática respiratória Mecânica respiratória Fotogrametria Recém-nascido This project has been develop in partnership with Trairí’s Health Science Faculty (FACISA – UFRN ) aiming to optimize the evaluation of thoracoabdominal movements in newborns, after receiving physiotherapeutic respiratory maneuver. However, in newborns, there is no effective method to assess respiratory kinematics. The traditional technique for respiratory volume measurement, called plethysmography, is not viable for clinical assessments in neonates. Some papers propose a different solution for this problem; by using lateral pictures of the newborn and processing those images in vector-based software, like CorelDraw or AutoCAD, where the user has to manually add a curve over the thoracoabdominal region to delimitate the wanted areas. On these softwares, each picture has to be individually analyzed, the focus area has to be calculated and converted to cm2, by applying an appropriated scale, which is derived from a standard length value in the image. After compiling all the images, the maximum and minimum point of the respiratory motion is acquired, providing enough data to evaluate the efficiency of the maneuver. Nevertheless, this process is slow and inaccurate, because it relies on user’s proficiency on said softwares. In this context, this project was developed, as a first functional and automated method to determine the thoracoabdominal volume from 2D images of neonates. Developed using MATLAB’s image processing toolboxes, the algorithm is capable of identifying the reference points and demarcating the thorax curvature automatically. This way, the application was able to process and quantify, sequentially, a larger set of images, always using the same standard, determining the maximum and minimum areas of the thorax and the abdomen throughout the entire respiratory motion of newborns, before and after applying the physiotherapeutic respiratory maneuver Este projeto tem sido desenvolvido em parceria com a Faculdade de Ciências da Saúde do Trairi (FACISA - UFRN) com o objetivo de otimizar a avaliação dos movimentos toracoabdominal em recém-nascidos, depois de receber manobra de fisioterapia respiratória. Em recém-nascidos, não existe nenhum método eficaz para avaliar a cinemática respiratória. A técnica tradicional para a medição do volume respiratório, chamado pletismografia, não é viável para avaliações clínicas de recém-nascidos. Alguns estudos propõem uma solução diferente para esse problema; usando imagens laterais do recém-nascido e processando essas imagens em software baseado em vetor, como CorelDraw ou AutoCAD, no qual o usuário tem que adicionar manualmente uma curva sobre a região toracoabdominal e delimitar as áreas desejadas. Em relação a esses programas, cada imagem é analisada individualmente, a área do foco é calculada e convertida para cm2, por aplicação de uma escala apropriada, a qual é derivada a partir de um valor de comprimento padrão na imagem. Após a análise de todas as imagens, o ponto máximo e mínimo do movimento respiratório é adquirido, proporcionando dados suficientes para avaliar a eficiência da manobra. No entanto, esse processo é lento e impreciso, porque depende da eficiência do usuário nos referidos softwares. Nesse contexto, este projeto foi desenvolvido, como um primeiro método funcional e automatizado para determinar o volume toracoabdominal a partir de imagens 2D de recém-nascidos. Desenvolvido usando caixas de ferramentas de processamento de imagem do MATLAB, o algoritmo é capaz de identificar os pontos de referência e de demarcar a curvatura do tórax automaticamente. Dessa forma, a aplicação foi capaz de processar e quantificar, sequencialmente, um conjunto maior de imagens, utilizando sempre o mesmo padrão, que determina as zonas mínima e máxima do tórax e abdômen durante todo o movimento respiratório de recém-nascidos, antes e após a aplicação das manobras de fisioterapia respiratória 2020-07-06T18:50:44Z 2020-07-06T18:50:44Z 2016-08-17 article OLIVEIRA, H. B.; PEREIRA, S. A.; VALE, B. E. C.; NAGEM, D. A. P. Sistema de reconhecimento de imagens para avaliação do movimento toracoabdominal em recém-nascidos. Revista Brasileira de Inovação Tecnológica Em Saúde. Disponível em: https://periodicos.ufrn.br/reb/article/view/9998. Acesso em: 03 jul. 2020. https://doi.org/10.18816/r-bits.v6i1.9998 2236-1103 https://repositorio.ufrn.br/jspui/handle/123456789/29461 10.18816/r-bits.v6i1.9998 pt_BR application/pdf Revista Brasileira de Inovação Tecnologica em Saúde