Corrosão do aço API K55 causada por salmouras de cloreto de sódio utilizadas na indústria de petróleo

Chloride brines are widely used in the petroleum industry, participating in the formulations of drilling muds, completion brines, etc. In some wells, the brines remain for long time trapped in the annular space above the packer. Because of this, they must have anticorrosive characteristics to gua...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Autor principal: Medeiros, Jonatas Gomes de
Outros Autores: Melo, Marcus Antonio de Freitas
Formato: Dissertação
Idioma:pt_BR
Publicado em: Brasil
Assuntos:
Endereço do item:https://repositorio.ufrn.br/jspui/handle/123456789/27128
Tags: Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
id ri-123456789-27128
record_format dspace
institution Repositório Institucional
collection RI - UFRN
language pt_BR
topic Inibidor de corrosão
Packer fluid
ANOVA
CNPQ::ENGENHARIAS::ENGENHARIA QUIMICA
spellingShingle Inibidor de corrosão
Packer fluid
ANOVA
CNPQ::ENGENHARIAS::ENGENHARIA QUIMICA
Medeiros, Jonatas Gomes de
Corrosão do aço API K55 causada por salmouras de cloreto de sódio utilizadas na indústria de petróleo
description Chloride brines are widely used in the petroleum industry, participating in the formulations of drilling muds, completion brines, etc. In some wells, the brines remain for long time trapped in the annular space above the packer. Because of this, they must have anticorrosive characteristics to guarantee a longer time between of interventions to replace equipaments. In this context, this work aims to evaluate the influence of pH and concentrations of sodium chloride, sodium bisulfite and corrosion inhibitor about the API K55 steel’s corrosion rate using a factorial design 2 4 with a central point and also verify the corrosion inhibitor’s efficiencies in the various brines’ compositions. Bases on NACE TM169, the corrosion rate tests were made based on the mass difference. The steel specimens were exposed to brines in roller oven at 90ºC and 274,20 psi of manometric pressure during 48 hours, being cleaning with hydrochloridric acid, tin II chloride and antimony III oxide solution. It was found the sodium bisulfite concentration effect wasn’t statistically significant in a 95% confidence interval. The effects of sodium chloride concentration, pH interaction with corrosion inhibitor concentration, pH and corrosion inhibitor were statistically significant within the same confidence interval. Using ANOVA, it was verified the statistical model that fit the observed values was predictive with determination coefficient equal to 99.46%. According to the results, the corrosion inhibitor’s highest efficiency was 72,90%, at pH 7.0 and 0,48% v/v of corrosion inhibitor.
author2 Melo, Marcus Antonio de Freitas
author_facet Melo, Marcus Antonio de Freitas
Medeiros, Jonatas Gomes de
format masterThesis
author Medeiros, Jonatas Gomes de
author_sort Medeiros, Jonatas Gomes de
title Corrosão do aço API K55 causada por salmouras de cloreto de sódio utilizadas na indústria de petróleo
title_short Corrosão do aço API K55 causada por salmouras de cloreto de sódio utilizadas na indústria de petróleo
title_full Corrosão do aço API K55 causada por salmouras de cloreto de sódio utilizadas na indústria de petróleo
title_fullStr Corrosão do aço API K55 causada por salmouras de cloreto de sódio utilizadas na indústria de petróleo
title_full_unstemmed Corrosão do aço API K55 causada por salmouras de cloreto de sódio utilizadas na indústria de petróleo
title_sort corrosão do aço api k55 causada por salmouras de cloreto de sódio utilizadas na indústria de petróleo
publisher Brasil
publishDate 2019
url https://repositorio.ufrn.br/jspui/handle/123456789/27128
work_keys_str_mv AT medeirosjonatasgomesde corrosaodoacoapik55causadaporsalmourasdecloretodesodioutilizadasnaindustriadepetroleo
_version_ 1773966053452283904
spelling ri-123456789-271282019-06-09T05:25:39Z Corrosão do aço API K55 causada por salmouras de cloreto de sódio utilizadas na indústria de petróleo Medeiros, Jonatas Gomes de Melo, Marcus Antonio de Freitas Silva, Djalma Ribeiro da Balaban, Rosângela de Carvalho Araújo Filho, Romero Gomes da Silva Inibidor de corrosão Packer fluid ANOVA CNPQ::ENGENHARIAS::ENGENHARIA QUIMICA Chloride brines are widely used in the petroleum industry, participating in the formulations of drilling muds, completion brines, etc. In some wells, the brines remain for long time trapped in the annular space above the packer. Because of this, they must have anticorrosive characteristics to guarantee a longer time between of interventions to replace equipaments. In this context, this work aims to evaluate the influence of pH and concentrations of sodium chloride, sodium bisulfite and corrosion inhibitor about the API K55 steel’s corrosion rate using a factorial design 2 4 with a central point and also verify the corrosion inhibitor’s efficiencies in the various brines’ compositions. Bases on NACE TM169, the corrosion rate tests were made based on the mass difference. The steel specimens were exposed to brines in roller oven at 90ºC and 274,20 psi of manometric pressure during 48 hours, being cleaning with hydrochloridric acid, tin II chloride and antimony III oxide solution. It was found the sodium bisulfite concentration effect wasn’t statistically significant in a 95% confidence interval. The effects of sodium chloride concentration, pH interaction with corrosion inhibitor concentration, pH and corrosion inhibitor were statistically significant within the same confidence interval. Using ANOVA, it was verified the statistical model that fit the observed values was predictive with determination coefficient equal to 99.46%. According to the results, the corrosion inhibitor’s highest efficiency was 72,90%, at pH 7.0 and 0,48% v/v of corrosion inhibitor. Salmouras de cloretos são muito utilizadas na indústria de petróleo, participando das formulações de fluidos de perfuração, fluidos de completação, etc. Em alguns poços, as salmouras permanecem por longos períodos aprisionadas no espaço anular acima do obturador. Por isso, elas devem possuir características anticorrosivas para garantir maior período de tempo entre as intervenções para troca de equipamentos. Neste contexto, o presente trabalho tem como objetivo avaliar a influência do pH e das concentrações de cloreto de sódio, de bissulfito de sódio e de inibidor de corrosão na taxa de corrosão do aço API K55 por meio de um planejamento fatorial 24 com um ponto central e verificar também as eficiências do inibidor de corrosão nas diversas composições de salmouras. Baseados na NACE TM169, os ensaios de taxa de corrosão foram realizados com base na diferença de massa, em que os cupons foram expostos as salmouras em estufa rotativa a 90ºC e 274,20 psi de pressão manométrica durante 48h, sendo decapados com solução de ácido clorídrico, cloreto de estanho II e óxido de antimônio III. Verificou-se que o efeito da concentração de bissulfito de sódio não foi estatisticamente significante num intervalo de 95% de confiança. Os efeitos da concentração de cloreto de sódio, da interação do pH com a concentração de inibidor de corrosão, do pH e do inibidor de corrosão foram estatisticamente significantes dentro do mesmo intervalo de confiança. Usando ANOVA, verificou-se que o modelo estatístico que melhor se ajustava aos dados foi preditivo com coeficiente de determinação de 99,46%. De acordo com os resultados, a maior eficiência do inibidor de corrosão foi de 72,90%, em pH 7,0 e concentração de 0,48% v/v de inibidor. 2019-06-04T23:21:21Z 2019-06-04T23:21:21Z 2019-02-25 masterThesis MEDEIROS, Jonatas Gomes de. Corrosão do aço API K55 causada por salmouras de cloreto de sódio utilizadas na indústria de petróleo. 2019. 107f. Dissertação (Mestrado em Engenharia Química) - Centro de Tecnologia, Universidade Federal do Rio Grande do Norte, Natal, 2019. https://repositorio.ufrn.br/jspui/handle/123456789/27128 pt_BR Acesso Aberto application/pdf Brasil UFRN PROGRAMA DE PÓS-GRADUAÇÃO EM ENGENHARIA QUÍMICA