Comportamento à tração de estaca helicoidal instrumentada submetida a carregamento cíclico em solo arenoso

Helical piles are foundations installed in the ground by means of torque to withstand of compression, traction and lateral loads. They offer advantages such as high productivity and installation with minimum noise and vibration. In this work, the pull-out behavior of instrumented helical piles su...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Autor principal: Farias, Manoel Leandro Araújo e
Outros Autores: Costa, Yuri Daniel Jatobá
Formato: Dissertação
Idioma:pt_BR
Publicado em: Brasil
Assuntos:
Endereço do item:https://repositorio.ufrn.br/jspui/handle/123456789/26863
Tags: Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
id ri-123456789-26863
record_format dspace
institution Repositório Institucional
collection RI - UFRN
language pt_BR
topic Estaca helicoidal
Instrumentação
Prova de carga à tração
Carregamento quase-estático
Areia
CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
spellingShingle Estaca helicoidal
Instrumentação
Prova de carga à tração
Carregamento quase-estático
Areia
CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
Farias, Manoel Leandro Araújo e
Comportamento à tração de estaca helicoidal instrumentada submetida a carregamento cíclico em solo arenoso
description Helical piles are foundations installed in the ground by means of torque to withstand of compression, traction and lateral loads. They offer advantages such as high productivity and installation with minimum noise and vibration. In this work, the pull-out behavior of instrumented helical piles subjected to cyclic loading in sandy soil is evaluated. The used pile had three bearing plates and was instrumented with electric resistance strain gauges in three sections along the shaft. Three pull-out load tests were performed: two with quasi-static cyclic loading and one with static loading, to verify the effects of cyclic loading. The tests with quasistatic loads were made with different values of average cyclic load and load amplitude. The results showed a great influence of the way in which the load increments were used, due to the densification and disturbance of the surrounding soil. The accumulated displacements tended to stabilize after the 10th cycle, low rates of mean displacement accumulation were not obtained and the number of cycles before failure showed to be dependent on the average load and the cyclic amplitude. The instrumented sections allowed to observe the reduction in the residual cyclic rigidity with the increase in depth along the shaft. The analysis of the mobilized loads in the bearing plates along the cycles, showed that the contribution to resistance from the lower bearing plate was responsible for most of the load capacity. It was observed that applied load levels and interaction factors between loading stages, which appear when the minimum load of a loading stage is lower than the maximum load of the previous stage, influenced the cyclical behavior of the soil-pile system by increasing the system rigidity and reducing corresponding displacements. Finally, the application of the quasi-static load cycles increased the static uplift capacity.
author2 Costa, Yuri Daniel Jatobá
author_facet Costa, Yuri Daniel Jatobá
Farias, Manoel Leandro Araújo e
format masterThesis
author Farias, Manoel Leandro Araújo e
author_sort Farias, Manoel Leandro Araújo e
title Comportamento à tração de estaca helicoidal instrumentada submetida a carregamento cíclico em solo arenoso
title_short Comportamento à tração de estaca helicoidal instrumentada submetida a carregamento cíclico em solo arenoso
title_full Comportamento à tração de estaca helicoidal instrumentada submetida a carregamento cíclico em solo arenoso
title_fullStr Comportamento à tração de estaca helicoidal instrumentada submetida a carregamento cíclico em solo arenoso
title_full_unstemmed Comportamento à tração de estaca helicoidal instrumentada submetida a carregamento cíclico em solo arenoso
title_sort comportamento à tração de estaca helicoidal instrumentada submetida a carregamento cíclico em solo arenoso
publisher Brasil
publishDate 2019
url https://repositorio.ufrn.br/jspui/handle/123456789/26863
work_keys_str_mv AT fariasmanoelleandroaraujoe comportamentoatracaodeestacahelicoidalinstrumentadasubmetidaacarregamentociclicoemsoloarenoso
AT fariasmanoelleandroaraujoe upliftbehaviorofaninstrumentedhelicalpilesubjectedtocyclicloadinginsandysoil
_version_ 1773961513763078144
spelling ri-123456789-268632019-05-26T05:31:43Z Comportamento à tração de estaca helicoidal instrumentada submetida a carregamento cíclico em solo arenoso Uplift behavior of an instrumented helical pile subjected to cyclic loading in sandy soil Farias, Manoel Leandro Araújo e Costa, Yuri Daniel Jatobá Silva Filho, José Neres da Soares, Wilson Cartaxo Estaca helicoidal Instrumentação Prova de carga à tração Carregamento quase-estático Areia CNPQ::ENGENHARIAS::ENGENHARIA CIVIL Helical piles are foundations installed in the ground by means of torque to withstand of compression, traction and lateral loads. They offer advantages such as high productivity and installation with minimum noise and vibration. In this work, the pull-out behavior of instrumented helical piles subjected to cyclic loading in sandy soil is evaluated. The used pile had three bearing plates and was instrumented with electric resistance strain gauges in three sections along the shaft. Three pull-out load tests were performed: two with quasi-static cyclic loading and one with static loading, to verify the effects of cyclic loading. The tests with quasistatic loads were made with different values of average cyclic load and load amplitude. The results showed a great influence of the way in which the load increments were used, due to the densification and disturbance of the surrounding soil. The accumulated displacements tended to stabilize after the 10th cycle, low rates of mean displacement accumulation were not obtained and the number of cycles before failure showed to be dependent on the average load and the cyclic amplitude. The instrumented sections allowed to observe the reduction in the residual cyclic rigidity with the increase in depth along the shaft. The analysis of the mobilized loads in the bearing plates along the cycles, showed that the contribution to resistance from the lower bearing plate was responsible for most of the load capacity. It was observed that applied load levels and interaction factors between loading stages, which appear when the minimum load of a loading stage is lower than the maximum load of the previous stage, influenced the cyclical behavior of the soil-pile system by increasing the system rigidity and reducing corresponding displacements. Finally, the application of the quasi-static load cycles increased the static uplift capacity. Estacas helicoidais são fundações instaladas no solo por meio de torque para suportar cargas de compressão, tração e lateral. Apresentam vantagens como alta produtividade e instalação com mínimo barulho e vibração. Neste trabalho é avaliado o comportamento a esforço de tração de estacas helicoidais instrumentadas e submetidas a carregamento cíclico em solo arenoso. A estaca utilizada possuía três hélices e foi instrumentada com extensômetros elétricos de resistência em três seções ao longo do fuste. Foram realizadas três provas de carga à tração, duas com carregamento cíclico quase-estático e uma com carregamento estático, para verificar os efeitos do carregamento cíclico. Os ensaios com carregamentos quase-estáticos foram feitos com valores diferentes de carga cíclica média e amplitude de carga. Os resultados mostraram uma grande influência do modo como os incrementos de carga foram empregados, devido atuarem no processo de densificação e perturbação do solo circunvizinho da estaca. Os deslocamentos acumulados tenderam a se estabilizar após o 10º ciclo, não foram obtidas baixas taxas de acumulação média de deslocamento e o número de ciclos antes da ruptura mostrou-se dependente da carga média e da amplitude cíclica. Com a instrumentação, foi constatada uma redução na rigidez cíclica residual com o aumento na profundidade ao longo do fuste. Através da análise das cargas mobilizadas nas hélices ao longo dos ciclos, se verificou que a contribuição de resistência proveniente da hélice da ponta foi responsável pela maior parte da capacidade de carga. Observou-se que os níveis de carga aplicados e os fatores de interação entre estágios de carga, os quais aparecem quando a carga mínima de uma etapa de carregamento é menor que a carga máxima da etapa anterior, influenciaram o comportamento cíclico do sistema solo-estaca de modo a promover rigidez e reduzir os deslocamentos correspondentes. Por fim, a aplicação dos ciclos de carga quase-estáticos proporcionou aumento na capacidade de carga estática à tração. 2019-04-05T22:20:30Z 2019-04-05T22:20:30Z 2019-02-14 masterThesis FARIAS, Manoel Leandro Araújo e. Comportamento à tração de estaca helicoidal instrumentada submetida a carregamento cíclico em solo arenoso. 2019. 99f. Dissertação (Mestrado em Engenharia Civil) - Centro de Tecnologia, Universidade Federal do Rio Grande do Norte, Natal, 2019. https://repositorio.ufrn.br/jspui/handle/123456789/26863 pt_BR Acesso Aberto application/pdf Brasil UFRN PROGRAMA DE PÓS-GRADUAÇÃO EM ENGENHARIA CIVIL