Identificação de faltas de alta impedância por análise de características cicloestacionárias

Conventional overcurrent protection systems are often not sensitized to the occurrence of high impedance faults, because these currents have a low amplitude. This type of disturbance causes damages to the ulilities, as well as can cause deaths of people and animals. Therefore, different identific...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Autor principal: Souza, Frankelene Pinheiro de
Outros Autores: Silveira, Luiz Felipe de Queiroz
Formato: Dissertação
Idioma:por
Publicado em: Brasil
Assuntos:
Endereço do item:https://repositorio.ufrn.br/jspui/handle/123456789/25032
Tags: Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
id ri-123456789-25032
record_format dspace
institution Repositório Institucional
collection RI - UFRN
language por
topic Falta de alta impedância
Análise cicloestacionária
Sistema de distribuição
CNPQ::ENGENHARIAS: ENGENHARIA MECATRÔNICA
spellingShingle Falta de alta impedância
Análise cicloestacionária
Sistema de distribuição
CNPQ::ENGENHARIAS: ENGENHARIA MECATRÔNICA
Souza, Frankelene Pinheiro de
Identificação de faltas de alta impedância por análise de características cicloestacionárias
description Conventional overcurrent protection systems are often not sensitized to the occurrence of high impedance faults, because these currents have a low amplitude. This type of disturbance causes damages to the ulilities, as well as can cause deaths of people and animals. Therefore, different identification methods of high impedance faults in electric power distribution systems have been proposed. The main difficulty found by these methods is due to noise interference on the signal, as well as the low fault overcurrent level. Therefore to search for efficient and reliable method to identify high impedance faults, which does not present the drawbacks found in the methods proposed in the literature, an innovative method is proposed that minimizes the noise interference on the signal, and uses characteristics statistics present on the signals with high impedance fault to identify them, and thus to differentiate them from other phenomena present in the electrical systems. Specifically, the method uses analysis of cyclostationary processes to extract cyclic autocorrelation information from the samples of the signals of interest by calculating the cyclic spectral density function. From this information, we can obtain descriptors that allow to classify at a later stage the faults of high impedance. Results indicated that the method is robust to noise and efficient in terms of correct classification rate of high impedance fault events, as well as the method does not emit false alerts to the system.
author2 Silveira, Luiz Felipe de Queiroz
author_facet Silveira, Luiz Felipe de Queiroz
Souza, Frankelene Pinheiro de
format masterThesis
author Souza, Frankelene Pinheiro de
author_sort Souza, Frankelene Pinheiro de
title Identificação de faltas de alta impedância por análise de características cicloestacionárias
title_short Identificação de faltas de alta impedância por análise de características cicloestacionárias
title_full Identificação de faltas de alta impedância por análise de características cicloestacionárias
title_fullStr Identificação de faltas de alta impedância por análise de características cicloestacionárias
title_full_unstemmed Identificação de faltas de alta impedância por análise de características cicloestacionárias
title_sort identificação de faltas de alta impedância por análise de características cicloestacionárias
publisher Brasil
publishDate 2018
url https://repositorio.ufrn.br/jspui/handle/123456789/25032
work_keys_str_mv AT souzafrankelenepinheirode identificacaodefaltasdealtaimpedanciaporanalisedecaracteristicascicloestacionarias
_version_ 1773960534112075776
spelling ri-123456789-250322019-01-30T20:31:28Z Identificação de faltas de alta impedância por análise de características cicloestacionárias Souza, Frankelene Pinheiro de Silveira, Luiz Felipe de Queiroz Costa, Flávio Bezerra Martins, Allan de Medeiros Lopes, Felipe Vigolvino Lira, George Rossany Soares de Falta de alta impedância Análise cicloestacionária Sistema de distribuição CNPQ::ENGENHARIAS: ENGENHARIA MECATRÔNICA Conventional overcurrent protection systems are often not sensitized to the occurrence of high impedance faults, because these currents have a low amplitude. This type of disturbance causes damages to the ulilities, as well as can cause deaths of people and animals. Therefore, different identification methods of high impedance faults in electric power distribution systems have been proposed. The main difficulty found by these methods is due to noise interference on the signal, as well as the low fault overcurrent level. Therefore to search for efficient and reliable method to identify high impedance faults, which does not present the drawbacks found in the methods proposed in the literature, an innovative method is proposed that minimizes the noise interference on the signal, and uses characteristics statistics present on the signals with high impedance fault to identify them, and thus to differentiate them from other phenomena present in the electrical systems. Specifically, the method uses analysis of cyclostationary processes to extract cyclic autocorrelation information from the samples of the signals of interest by calculating the cyclic spectral density function. From this information, we can obtain descriptors that allow to classify at a later stage the faults of high impedance. Results indicated that the method is robust to noise and efficient in terms of correct classification rate of high impedance fault events, as well as the method does not emit false alerts to the system. O Conselho Nacional de Desenvolvimento Científico e Tecnológico - CNPq Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) Os sistemas de proteção convencionais baseados em sobrecorrente, de um modo geral, não se sensibilizam com a ocorrência de faltas de alta impedância, pois essas correntes apresentam baixa amplitude. Esse tipo de distúrbio causa prejuízos às concessionárias, como também, pode causar mortes de pessoas e animais. Diante disso, distintos métodos para a identificação das faltas de alta impedância em sistemas de distribuição de energia elétrica vêm sendo propostos. A principal dificuldade encontrada por esses métodos é devido a interferência do ruído no sinal, assim como o baixo nível de sobrecorrente de falta. Diante da busca por um método seguro, eficiente e confiável para identificar as faltas de alta impedância, e que não apresente os inconvenientes encontrados nos métodos proposto na literatura, propõe-se um método inovador que minimiza a interferência do ruído no sinal, e utiliza características estatísticas presentes nos sinais com falta de alta impedância para os identificar, e assim os diferenciar de outros fenômenos presentes nos sistemas elétricos. Especificamente, o método usa análise de processos cicloestacionários para extrair informações de autocorrelação cíclica das amostras dos sinais de interesse, pelo cálculo da função densidade espectral cíclica. A partir dessas informações, podese obter descritores que permitem classificar em uma etapa posterior as faltas de alta impedância. Resultados indicaram que o método é robusto ao ruído e eficiente em termos de taxa de classificação correta dos eventos de falta de alta impedância, como também o método não emite falsos alertas ao sistema. 2018-04-10T19:21:14Z 2018-04-10T19:21:14Z 2017-12-20 masterThesis SOUZA, Frankelene Pinheiro de. Identificação de faltas de alta impedância por análise de características cicloestacionárias. 2017. 93f. Dissertação (Mestrado em Engenharia Mecatrônica) - Centro de Tecnologia, Universidade Federal do Rio Grande do Norte, Natal, 2017. https://repositorio.ufrn.br/jspui/handle/123456789/25032 por Acesso Aberto application/pdf Brasil UFRN PROGRAMA DE PÓS-GRADUAÇÃO EM ENGENHARIA MECATRÔNICA