Identificação de faltas de alta impedância por análise de características cicloestacionárias
Conventional overcurrent protection systems are often not sensitized to the occurrence of high impedance faults, because these currents have a low amplitude. This type of disturbance causes damages to the ulilities, as well as can cause deaths of people and animals. Therefore, different identific...
Na minha lista:
Autor principal: | |
---|---|
Outros Autores: | |
Formato: | Dissertação |
Idioma: | por |
Publicado em: |
Brasil
|
Assuntos: | |
Endereço do item: | https://repositorio.ufrn.br/jspui/handle/123456789/25032 |
Tags: |
Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
|
id |
ri-123456789-25032 |
---|---|
record_format |
dspace |
institution |
Repositório Institucional |
collection |
RI - UFRN |
language |
por |
topic |
Falta de alta impedância Análise cicloestacionária Sistema de distribuição CNPQ::ENGENHARIAS: ENGENHARIA MECATRÔNICA |
spellingShingle |
Falta de alta impedância Análise cicloestacionária Sistema de distribuição CNPQ::ENGENHARIAS: ENGENHARIA MECATRÔNICA Souza, Frankelene Pinheiro de Identificação de faltas de alta impedância por análise de características cicloestacionárias |
description |
Conventional overcurrent protection systems are often not sensitized to the occurrence
of high impedance faults, because these currents have a low amplitude. This type of disturbance
causes damages to the ulilities, as well as can cause deaths of people and animals.
Therefore, different identification methods of high impedance faults in electric power distribution
systems have been proposed. The main difficulty found by these methods is due
to noise interference on the signal, as well as the low fault overcurrent level. Therefore
to search for efficient and reliable method to identify high impedance faults, which does
not present the drawbacks found in the methods proposed in the literature, an innovative
method is proposed that minimizes the noise interference on the signal, and uses characteristics
statistics present on the signals with high impedance fault to identify them, and thus
to differentiate them from other phenomena present in the electrical systems. Specifically,
the method uses analysis of cyclostationary processes to extract cyclic autocorrelation information
from the samples of the signals of interest by calculating the cyclic spectral
density function. From this information, we can obtain descriptors that allow to classify
at a later stage the faults of high impedance. Results indicated that the method is robust to
noise and efficient in terms of correct classification rate of high impedance fault events,
as well as the method does not emit false alerts to the system. |
author2 |
Silveira, Luiz Felipe de Queiroz |
author_facet |
Silveira, Luiz Felipe de Queiroz Souza, Frankelene Pinheiro de |
format |
masterThesis |
author |
Souza, Frankelene Pinheiro de |
author_sort |
Souza, Frankelene Pinheiro de |
title |
Identificação de faltas de alta impedância por análise de características cicloestacionárias |
title_short |
Identificação de faltas de alta impedância por análise de características cicloestacionárias |
title_full |
Identificação de faltas de alta impedância por análise de características cicloestacionárias |
title_fullStr |
Identificação de faltas de alta impedância por análise de características cicloestacionárias |
title_full_unstemmed |
Identificação de faltas de alta impedância por análise de características cicloestacionárias |
title_sort |
identificação de faltas de alta impedância por análise de características cicloestacionárias |
publisher |
Brasil |
publishDate |
2018 |
url |
https://repositorio.ufrn.br/jspui/handle/123456789/25032 |
work_keys_str_mv |
AT souzafrankelenepinheirode identificacaodefaltasdealtaimpedanciaporanalisedecaracteristicascicloestacionarias |
_version_ |
1773960534112075776 |
spelling |
ri-123456789-250322019-01-30T20:31:28Z Identificação de faltas de alta impedância por análise de características cicloestacionárias Souza, Frankelene Pinheiro de Silveira, Luiz Felipe de Queiroz Costa, Flávio Bezerra Martins, Allan de Medeiros Lopes, Felipe Vigolvino Lira, George Rossany Soares de Falta de alta impedância Análise cicloestacionária Sistema de distribuição CNPQ::ENGENHARIAS: ENGENHARIA MECATRÔNICA Conventional overcurrent protection systems are often not sensitized to the occurrence of high impedance faults, because these currents have a low amplitude. This type of disturbance causes damages to the ulilities, as well as can cause deaths of people and animals. Therefore, different identification methods of high impedance faults in electric power distribution systems have been proposed. The main difficulty found by these methods is due to noise interference on the signal, as well as the low fault overcurrent level. Therefore to search for efficient and reliable method to identify high impedance faults, which does not present the drawbacks found in the methods proposed in the literature, an innovative method is proposed that minimizes the noise interference on the signal, and uses characteristics statistics present on the signals with high impedance fault to identify them, and thus to differentiate them from other phenomena present in the electrical systems. Specifically, the method uses analysis of cyclostationary processes to extract cyclic autocorrelation information from the samples of the signals of interest by calculating the cyclic spectral density function. From this information, we can obtain descriptors that allow to classify at a later stage the faults of high impedance. Results indicated that the method is robust to noise and efficient in terms of correct classification rate of high impedance fault events, as well as the method does not emit false alerts to the system. O Conselho Nacional de Desenvolvimento Científico e Tecnológico - CNPq Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) Os sistemas de proteção convencionais baseados em sobrecorrente, de um modo geral, não se sensibilizam com a ocorrência de faltas de alta impedância, pois essas correntes apresentam baixa amplitude. Esse tipo de distúrbio causa prejuízos às concessionárias, como também, pode causar mortes de pessoas e animais. Diante disso, distintos métodos para a identificação das faltas de alta impedância em sistemas de distribuição de energia elétrica vêm sendo propostos. A principal dificuldade encontrada por esses métodos é devido a interferência do ruído no sinal, assim como o baixo nível de sobrecorrente de falta. Diante da busca por um método seguro, eficiente e confiável para identificar as faltas de alta impedância, e que não apresente os inconvenientes encontrados nos métodos proposto na literatura, propõe-se um método inovador que minimiza a interferência do ruído no sinal, e utiliza características estatísticas presentes nos sinais com falta de alta impedância para os identificar, e assim os diferenciar de outros fenômenos presentes nos sistemas elétricos. Especificamente, o método usa análise de processos cicloestacionários para extrair informações de autocorrelação cíclica das amostras dos sinais de interesse, pelo cálculo da função densidade espectral cíclica. A partir dessas informações, podese obter descritores que permitem classificar em uma etapa posterior as faltas de alta impedância. Resultados indicaram que o método é robusto ao ruído e eficiente em termos de taxa de classificação correta dos eventos de falta de alta impedância, como também o método não emite falsos alertas ao sistema. 2018-04-10T19:21:14Z 2018-04-10T19:21:14Z 2017-12-20 masterThesis SOUZA, Frankelene Pinheiro de. Identificação de faltas de alta impedância por análise de características cicloestacionárias. 2017. 93f. Dissertação (Mestrado em Engenharia Mecatrônica) - Centro de Tecnologia, Universidade Federal do Rio Grande do Norte, Natal, 2017. https://repositorio.ufrn.br/jspui/handle/123456789/25032 por Acesso Aberto application/pdf Brasil UFRN PROGRAMA DE PÓS-GRADUAÇÃO EM ENGENHARIA MECATRÔNICA |