Contribuição da poliacrilamida parcialmente hidrolisada em associação com a bentonita em fluidos de perfuração aquosos

In this study, we investigated the effect of addition of partially hydrolyzed polyacrylamide (HPAM) and bentonite in the physicochemical properties of acquous drilling fluids. Two formulations were evaluated: F1 formulation, which was used as reference, containing carboxymethylcellulose (CMC), ma...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Autor principal: Costa, Rosimeire Filgueira
Outros Autores: Balaban, Rosângela de Carvalho
Formato: Dissertação
Idioma:por
Publicado em: Universidade Federal do Rio Grande do Norte
Assuntos:
Endereço do item:https://repositorio.ufrn.br/jspui/handle/123456789/20287
Tags: Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
id ri-123456789-20287
record_format dspace
institution Repositório Institucional
collection RI - UFRN
language por
topic HPAM
Bentonita
Fluido de perfuração
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
spellingShingle HPAM
Bentonita
Fluido de perfuração
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
Costa, Rosimeire Filgueira
Contribuição da poliacrilamida parcialmente hidrolisada em associação com a bentonita em fluidos de perfuração aquosos
description In this study, we investigated the effect of addition of partially hydrolyzed polyacrylamide (HPAM) and bentonite in the physicochemical properties of acquous drilling fluids. Two formulations were evaluated: F1 formulation, which was used as reference, containing carboxymethylcellulose (CMC), magnesium oxide (MgO), calcite (calcium carbonate - CaCO3 ), xanthan gum, sodium chloride (NaCl) and triazine (bactericidal); and F2, containig HPAM steady of CMC and bentonite in substituition of calcite. The prepared fluids were characterized by rheological properties, lubricity and fluid loss. Calcite was characterized by granulometry and thermal gravimetric analysis (TGA). The formulation F2 presented filtration control at 93◦C 34 mL while F1 had total filtration. The lubricity coefficient was 0.1623 for F2 and 0.2542 for F1, causing reduction in torque of 25% for F1 and 52 % for F2, compared to water. In the temperature of 49 ◦C and shear rate of 1022 s −1 , the apparent viscosities were 25, 5 and 48 cP for F1 and F2 formulation, respectively, showing greater thermal resistance to F2. With the confirmation of higher thermal stability of F2, factorial design was conducted in order to determine the HPAM and of bentonite concentrations that resulted in the better performance of the fluids. The statistical design response surfaces indicated the best concentrations of HPAM (4.3g/L) and bentonite (28.5 g/L) to achieve improved properties of the fluids (apparent viscosity, plastic viscosity, yield point and fluid loss) with 95% confidence, as well as the correlations between these factors (HPAM and bentonite concentrations). The thermal aging tests indicated that the formulations containing HPAM and bentonite may be used to the maximum temperature until 150 ◦C. The analyze of the filter cake formed after filtration of fluids by X-ray diffraction showed specific interactions between the bentonite and HPAM, explaining the greater thermal stability of F2 compared to the fluid F1, that supports maximum temperature of 93 ◦C.
author2 Balaban, Rosângela de Carvalho
author_facet Balaban, Rosângela de Carvalho
Costa, Rosimeire Filgueira
format masterThesis
author Costa, Rosimeire Filgueira
author_sort Costa, Rosimeire Filgueira
title Contribuição da poliacrilamida parcialmente hidrolisada em associação com a bentonita em fluidos de perfuração aquosos
title_short Contribuição da poliacrilamida parcialmente hidrolisada em associação com a bentonita em fluidos de perfuração aquosos
title_full Contribuição da poliacrilamida parcialmente hidrolisada em associação com a bentonita em fluidos de perfuração aquosos
title_fullStr Contribuição da poliacrilamida parcialmente hidrolisada em associação com a bentonita em fluidos de perfuração aquosos
title_full_unstemmed Contribuição da poliacrilamida parcialmente hidrolisada em associação com a bentonita em fluidos de perfuração aquosos
title_sort contribuição da poliacrilamida parcialmente hidrolisada em associação com a bentonita em fluidos de perfuração aquosos
publisher Universidade Federal do Rio Grande do Norte
publishDate 2016
url https://repositorio.ufrn.br/jspui/handle/123456789/20287
work_keys_str_mv AT costarosimeirefilgueira contribuicaodapoliacrilamidaparcialmentehidrolisadaemassociacaocomabentonitaemfluidosdeperfuracaoaquosos
_version_ 1773959458475474944
spelling ri-123456789-202872017-11-03T21:08:37Z Contribuição da poliacrilamida parcialmente hidrolisada em associação com a bentonita em fluidos de perfuração aquosos Costa, Rosimeire Filgueira Balaban, Rosângela de Carvalho http://lattes.cnpq.br/9799631611663560 http://lattes.cnpq.br/7711521318854102 Fagundes, Fábio Pereira http://lattes.cnpq.br/8770334212266182 Bicudo, Tatiana de Campos http://lattes.cnpq.br/2712586287719863 HPAM Bentonita Fluido de perfuração CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA In this study, we investigated the effect of addition of partially hydrolyzed polyacrylamide (HPAM) and bentonite in the physicochemical properties of acquous drilling fluids. Two formulations were evaluated: F1 formulation, which was used as reference, containing carboxymethylcellulose (CMC), magnesium oxide (MgO), calcite (calcium carbonate - CaCO3 ), xanthan gum, sodium chloride (NaCl) and triazine (bactericidal); and F2, containig HPAM steady of CMC and bentonite in substituition of calcite. The prepared fluids were characterized by rheological properties, lubricity and fluid loss. Calcite was characterized by granulometry and thermal gravimetric analysis (TGA). The formulation F2 presented filtration control at 93◦C 34 mL while F1 had total filtration. The lubricity coefficient was 0.1623 for F2 and 0.2542 for F1, causing reduction in torque of 25% for F1 and 52 % for F2, compared to water. In the temperature of 49 ◦C and shear rate of 1022 s −1 , the apparent viscosities were 25, 5 and 48 cP for F1 and F2 formulation, respectively, showing greater thermal resistance to F2. With the confirmation of higher thermal stability of F2, factorial design was conducted in order to determine the HPAM and of bentonite concentrations that resulted in the better performance of the fluids. The statistical design response surfaces indicated the best concentrations of HPAM (4.3g/L) and bentonite (28.5 g/L) to achieve improved properties of the fluids (apparent viscosity, plastic viscosity, yield point and fluid loss) with 95% confidence, as well as the correlations between these factors (HPAM and bentonite concentrations). The thermal aging tests indicated that the formulations containing HPAM and bentonite may be used to the maximum temperature until 150 ◦C. The analyze of the filter cake formed after filtration of fluids by X-ray diffraction showed specific interactions between the bentonite and HPAM, explaining the greater thermal stability of F2 compared to the fluid F1, that supports maximum temperature of 93 ◦C. Neste trabalho, foi investigado o efeito da adição de poliacrilamida parcialmente hidrolisada (HPAM) e bentonita nas propriedades físico-químicas de fluidos de perfuração aquosos. Duas formulações foram avaliadas: a formulação F1, que foi utilizada como referência, contendo carboximetilcelulose (CMC), óxido de magnésio (MgO), calcita (carbonato de cálcio – CaCO3 ), goma xantana, cloreto de sódio (NaCl) e triazina (bactericida); e a formulação F2, contendo HPAM em substituição a CMC e bentonita em substituição à calcita. Os fluidos preparados foram caracterizados quanto às propriedades reológicas, a lubricidade e o volume de filtrado. A calcita foi caracterizada por granulometria e análise termogravimétrica (TGA). A formulação F2 apresentou controle de filtração à temperatura de 93 ◦C 34 mL, enquanto a F1 apresentou filtração total. O coeficiente de lubricidade da formulação F2 foi 0, 1623 e o da F1 0, 2542, acarretando uma redução de torque de 25% para F1 e de 52% para F2, comparado à água. Na temperatura de 49 ◦C e taxa de cisalhamento 1022 s −1 , as viscosidades aparentes foram 25, 5 e 48 cP para as formulações F1 e F2, respectivamente, evidenciando maior resistência térmica para F2. Com a comprovação da maior estabilidade térmica de F2, um planejamento fatorial foi realizado, a fim de determinar as concentrações de HPAM e de bentonita de melhor desempenho nos fluidos. O planejamento estatístico gerou superfícies de resposta indicando as melhores concentrações de HPAM (4, 3 g/L) e de bentonita (28, 5 g/L) para se alcançar propriedades melhoradas dos fluidos (viscosidade aparente, viscosidade plástica, limite de escoamento e volume de filtrado) com 95% de confiança, assim como as correlações entre esses fatores (concentrações de HPAM e bentonita). Os testes de envelhecimento térmico indicaram que as formulações contendo HPAM e bentonita podem ser utilizadas à temperatura máxima de 150 ◦C. A análise do reboco formado após filtração dos fluidos por Difração de Raios X indicou interações específicas entre a HPAM e a bentonita, justificando a maior estabilidade térmica do fluido F2 comparado ao F1, que suporta temperatura máxima de 93 ◦C. 2016-04-27T00:02:09Z 2016-04-27T00:02:09Z 2015-07-24 masterThesis COSTA, Rosimeire Filgueira. Contribuição da poliacrilamida parcialmente hidrolisada em associação com a bentonita em fluidos de perfuração aquosos. 2015. 56f. Dissertação (Mestrado em Química) - Centro de Ciências Exatas e da Terra, Universidade Federal do Rio Grande do Norte, Natal, 2015. https://repositorio.ufrn.br/jspui/handle/123456789/20287 por Acesso Aberto application/pdf Universidade Federal do Rio Grande do Norte Brasil UFRN PROGRAMA DE PÓS-GRADUAÇÃO EM QUÍMICA