Determinação de CD, PB, e TL em água produzida por HR-CS GF AAS após extração em ponto nuvem

Produced water is a major problem associated with the crude oil extraction activity. The monitoring of the levels of metals in the waste is constant and requires the use of sensitive analytical techniques. However, the determination of trace elements can often require a pre-concentration step. Th...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Autor principal: Bezerra, Breno Gustavo Porfírio
Outros Autores: Silva, Djalma Ribeiro da
Formato: Dissertação
Idioma:por
Publicado em: Universidade Federal do Rio Grande do Norte
Assuntos:
Endereço do item:https://repositorio.ufrn.br/jspui/handle/123456789/19671
Tags: Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
id ri-123456789-19671
record_format dspace
institution Repositório Institucional
collection RI - UFRN
language por
topic Água produzida
Extração e pré-concentração
HR- CS GF AAS
Box Behnken
Ddtp
Triton x – 114
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
spellingShingle Água produzida
Extração e pré-concentração
HR- CS GF AAS
Box Behnken
Ddtp
Triton x – 114
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
Bezerra, Breno Gustavo Porfírio
Determinação de CD, PB, e TL em água produzida por HR-CS GF AAS após extração em ponto nuvem
description Produced water is a major problem associated with the crude oil extraction activity. The monitoring of the levels of metals in the waste is constant and requires the use of sensitive analytical techniques. However, the determination of trace elements can often require a pre-concentration step. The objective of this study was to develop a simple and rapid analytical method for the extraction and pre-concentration based on extraction phenomenon cloud point for the determination of Cd, Pb and Tl in produced water samples by spectrometry of high resolution Absorption source continues and atomization graphite furnace. The Box Behnken design was used to obtain the optimal condition of extraction of analytes. The factors were evaluated: concentration of complexing agent (o,o-dietilditilfosfato ammonium, DDTP), the concentration of hydrochloric acid and concentration of surfactant (Triton X -114). The optimal condition obtained through extraction was: 0,6% m v-1 DDTP, HCl 0,3 mol L-1 and 0,2% m v-1 of Triton X - 114 for Pb; 0,7% m v-1 DDTP, HCl 0,8 mol L-1 and 0,2% m v-1 Triton X-114 for Cd. For Tl was evidenced that best extraction condition occurs with no DDTP, the extraction conditions were HCl 1,0 mol L-1 e 1,0% m v-1 de Triton X - 114. The limits of detection for the proposed method were 0,005 µg L-1 , 0,03 µg L-1 and 0,09 µg L-1 to Cd, Pb and Tl, Respectively. Enrichment factors Were greater than 10 times. The method was applied to the water produced in the Potiguar basin, and addition and recovery tests were performed, and values were between 81% and 120%. The precision was expressed with relative standard deviation (RSD) is less than 5%
author2 Silva, Djalma Ribeiro da
author_facet Silva, Djalma Ribeiro da
Bezerra, Breno Gustavo Porfírio
format masterThesis
author Bezerra, Breno Gustavo Porfírio
author_sort Bezerra, Breno Gustavo Porfírio
title Determinação de CD, PB, e TL em água produzida por HR-CS GF AAS após extração em ponto nuvem
title_short Determinação de CD, PB, e TL em água produzida por HR-CS GF AAS após extração em ponto nuvem
title_full Determinação de CD, PB, e TL em água produzida por HR-CS GF AAS após extração em ponto nuvem
title_fullStr Determinação de CD, PB, e TL em água produzida por HR-CS GF AAS após extração em ponto nuvem
title_full_unstemmed Determinação de CD, PB, e TL em água produzida por HR-CS GF AAS após extração em ponto nuvem
title_sort determinação de cd, pb, e tl em água produzida por hr-cs gf aas após extração em ponto nuvem
publisher Universidade Federal do Rio Grande do Norte
publishDate 2016
url https://repositorio.ufrn.br/jspui/handle/123456789/19671
work_keys_str_mv AT bezerrabrenogustavoporfirio determinacaodecdpbetlemaguaproduzidaporhrcsgfaasaposextracaoempontonuvem
AT bezerrabrenogustavoporfirio determinationofcdpbandtlproducedwaterbyhrcsgfaasafterextractionpointincloud
_version_ 1773965068725125120
spelling ri-123456789-196712017-10-31T23:13:11Z Determinação de CD, PB, e TL em água produzida por HR-CS GF AAS após extração em ponto nuvem Determination of Cd, Pb, and Tl produced water by HR-CS GF AAS after extraction point in cloud Bezerra, Breno Gustavo Porfírio Silva, Djalma Ribeiro da http://lattes.cnpq.br/1187996246301757 http://lattes.cnpq.br/2791074318745945 Maranhão, Tatiane de Andrade http://lattes.cnpq.br/2283703059305052 Huitle, Carlos Alberto Martinez http://lattes.cnpq.br/2485073932883264 Araújo, Rennan Geovanny Oliveira http://lattes.cnpq.br/3891753417538363 Água produzida Extração e pré-concentração HR- CS GF AAS Box Behnken Ddtp Triton x – 114 CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA Produced water is a major problem associated with the crude oil extraction activity. The monitoring of the levels of metals in the waste is constant and requires the use of sensitive analytical techniques. However, the determination of trace elements can often require a pre-concentration step. The objective of this study was to develop a simple and rapid analytical method for the extraction and pre-concentration based on extraction phenomenon cloud point for the determination of Cd, Pb and Tl in produced water samples by spectrometry of high resolution Absorption source continues and atomization graphite furnace. The Box Behnken design was used to obtain the optimal condition of extraction of analytes. The factors were evaluated: concentration of complexing agent (o,o-dietilditilfosfato ammonium, DDTP), the concentration of hydrochloric acid and concentration of surfactant (Triton X -114). The optimal condition obtained through extraction was: 0,6% m v-1 DDTP, HCl 0,3 mol L-1 and 0,2% m v-1 of Triton X - 114 for Pb; 0,7% m v-1 DDTP, HCl 0,8 mol L-1 and 0,2% m v-1 Triton X-114 for Cd. For Tl was evidenced that best extraction condition occurs with no DDTP, the extraction conditions were HCl 1,0 mol L-1 e 1,0% m v-1 de Triton X - 114. The limits of detection for the proposed method were 0,005 µg L-1 , 0,03 µg L-1 and 0,09 µg L-1 to Cd, Pb and Tl, Respectively. Enrichment factors Were greater than 10 times. The method was applied to the water produced in the Potiguar basin, and addition and recovery tests were performed, and values were between 81% and 120%. The precision was expressed with relative standard deviation (RSD) is less than 5% A água produzida representa um grande problema associado com a atividade de extração de óleo bruto. O monitoramento dos níveis de metais nos resíduos é constante e requer a utilização de técnicas analíticas sensíveis. No entanto, a determinação de elementos traço muitas vezes pode exigir uma etapa de pré-concentração. O objetivo deste trabalho foi desenvolver um método analítico simples e rápido para a extração e pré-concentração baseada no fenômeno de extração no ponto nuvem para a determinação do Cd, Pb e Tl em água produzida amostras por Espectrometria de Absorção de alta resolução com fonte continua e atomização em forno de grafite. Um planejamento Box Behnken foi usado para obter a condição ideal de extração dos analitos. Os fatores avaliados foram: concentração do agente complexante (o,odietilditilfosfato amônio, DDTP), a concentração do ácido clorídrico e concentração do surfactante (Triton X -114). A condição ideal de extração foi obtida com: 0,6% m v -1 DDTP, HCl 0,3 mol L-1 e 0,2% m v -1 de Triton X - 114 para o Pb; 0,7% m v -1 DDTP, HCl 0,8 mol L-1 e 0,2% m v -1 Triton X-114 para Cd. Para o Tl foi evidenciado que melhor condição de extração se dá com ausência de DDTP, as condições de extração foram então HCl 1,0 mol L-1 e 1,0% m v -1 de Triton X - 114. Os limites de detecção para o método proposto, foram 0,02 µg L-1 , 0,004 µg L-1 e 0,06 µg L-1 para o Pb, Cd e Tl, respectivamente. Os fatores de enriquecimento foram superiores a 10 vezes. O método foi aplicado para a água produzida da bacia Potiguar, e testes de adição e recuperação foram realizados, e valores ficaram entre 81% e 120%. A precisão foi expressa com desvio padrão relativo (RSD) foi inferior a 5% 2016-01-28T19:06:56Z 2016-01-28T19:06:56Z 2014-11-03 masterThesis BEZERRA, Breno Gustavo Porfírio. Determinação de CD, PB, e TL em água produzida por HR-CS GF AAS após extração em ponto nuvem. 2014. 91f. Dissertação (Mestrado em Química) - Centro de Ciências Exatas e da Terra, Universidade Federal do Rio Grande do Norte, Natal, 2014. https://repositorio.ufrn.br/jspui/handle/123456789/19671 por Acesso Aberto application/pdf Universidade Federal do Rio Grande do Norte Brasil UFRN PROGRAMA DE PÓS-GRADUAÇÃO EM QUÍMICA