Adaptação eletrônica de um leitor mecânico de coto, investigação e desenvolvimento de interface CAD

Due to advances in the manufacturing process of orthopedic prostheses, the need for better quality shape reading techniques (i.e. with less uncertainty) of the residual limb of amputees became a challenge. To overcome these problems means to be able in obtaining accurate geometry information of the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: Lacerda, Ivan Max Freire de
Weitere Verfasser: Guerra, ângelo Roncalli de Oliveira
Format: Dissertação
Sprache:por
Veröffentlicht: Universidade Federal do Rio Grande do Norte
Schlagworte:
Online Zugang:https://repositorio.ufrn.br/jspui/handle/123456789/15564
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
id ri-123456789-15564
record_format dspace
institution Repositório Institucional
collection RI - UFRN
language por
topic Leitor mecânico
Prótese ortopédica
Scanner mecânico - protótipo
Mecanic reador
Ortopedic prototype
Mecanic scanner - prototype
CNPQ::ENGENHARIAS::ENGENHARIA MECANICA
spellingShingle Leitor mecânico
Prótese ortopédica
Scanner mecânico - protótipo
Mecanic reador
Ortopedic prototype
Mecanic scanner - prototype
CNPQ::ENGENHARIAS::ENGENHARIA MECANICA
Lacerda, Ivan Max Freire de
Adaptação eletrônica de um leitor mecânico de coto, investigação e desenvolvimento de interface CAD
description Due to advances in the manufacturing process of orthopedic prostheses, the need for better quality shape reading techniques (i.e. with less uncertainty) of the residual limb of amputees became a challenge. To overcome these problems means to be able in obtaining accurate geometry information of the limb and, consequently, better manufacturing processes of both transfemural and transtibial prosthetic sockets. The key point for this task is to customize these readings trying to be as faithful as possible to the real profile of each patient. Within this context, firstly two prototype versions (α and β) of a 3D mechanical scanner for reading residual limbs shape based on reverse engineering techniques were designed. Prototype β is an improved version of prototype α, despite remaining working in analogical mode. Both prototypes are capable of producing a CAD representation of the limb via appropriated graphical sheets and were conceived to work purely by mechanical means. The first results were encouraging as they were able to achieve a great decrease concerning the degree of uncertainty of measurements when compared to traditional methods that are very inaccurate and outdated. For instance, it's not unusual to see these archaic methods in action by making use of ordinary home kind measure-tapes for exploring the limb's shape. Although prototype β improved the readings, it still required someone to input the plotted points (i.e. those marked in disk shape graphical sheets) to an academic CAD software called OrtoCAD. This task is performed by manual typing which is time consuming and carries very limited reliability. Furthermore, the number of coordinates obtained from the purely mechanical system is limited to sub-divisions of the graphical sheet (it records a point every 10 degrees with a resolution of one millimeter). These drawbacks were overcome by designing the second release of prototype β in which it was developed an electronic variation of the reading table components now capable of performing an automatic reading (i.e. no human intervention in digital mode). An interface software (i.e. drive) was built to facilitate data transfer. Much better results were obtained meaning less degree of uncertainty (it records a point every 2 degrees with a resolution of 1/10 mm). Additionally, it was proposed an algorithm to convert the CAD geometry, used by OrtoCAD, to an appropriate format and enabling the use of rapid prototyping equipment aiming future automation of the manufacturing process of prosthetic sockets.
author2 Guerra, ângelo Roncalli de Oliveira
author_facet Guerra, ângelo Roncalli de Oliveira
Lacerda, Ivan Max Freire de
format masterThesis
author Lacerda, Ivan Max Freire de
author_sort Lacerda, Ivan Max Freire de
title Adaptação eletrônica de um leitor mecânico de coto, investigação e desenvolvimento de interface CAD
title_short Adaptação eletrônica de um leitor mecânico de coto, investigação e desenvolvimento de interface CAD
title_full Adaptação eletrônica de um leitor mecânico de coto, investigação e desenvolvimento de interface CAD
title_fullStr Adaptação eletrônica de um leitor mecânico de coto, investigação e desenvolvimento de interface CAD
title_full_unstemmed Adaptação eletrônica de um leitor mecânico de coto, investigação e desenvolvimento de interface CAD
title_sort adaptação eletrônica de um leitor mecânico de coto, investigação e desenvolvimento de interface cad
publisher Universidade Federal do Rio Grande do Norte
publishDate 2014
url https://repositorio.ufrn.br/jspui/handle/123456789/15564
work_keys_str_mv AT lacerdaivanmaxfreirede adaptacaoeletronicadeumleitormecanicodecotoinvestigacaoedesenvolvimentodeinterfacecad
_version_ 1773957524328808448
spelling ri-123456789-155642017-11-01T15:14:45Z Adaptação eletrônica de um leitor mecânico de coto, investigação e desenvolvimento de interface CAD Lacerda, Ivan Max Freire de Guerra, ângelo Roncalli de Oliveira http://lattes.cnpq.br/2242625869596822 http://lattes.cnpq.br/7353332474621022 Lima, Carlos Magno de http://lattes.cnpq.br/2682764296612645 Queiroz, William Fernandes de http://lattes.cnpq.br/9535572564134421 Leitor mecânico Prótese ortopédica Scanner mecânico - protótipo Mecanic reador Ortopedic prototype Mecanic scanner - prototype CNPQ::ENGENHARIAS::ENGENHARIA MECANICA Due to advances in the manufacturing process of orthopedic prostheses, the need for better quality shape reading techniques (i.e. with less uncertainty) of the residual limb of amputees became a challenge. To overcome these problems means to be able in obtaining accurate geometry information of the limb and, consequently, better manufacturing processes of both transfemural and transtibial prosthetic sockets. The key point for this task is to customize these readings trying to be as faithful as possible to the real profile of each patient. Within this context, firstly two prototype versions (α and β) of a 3D mechanical scanner for reading residual limbs shape based on reverse engineering techniques were designed. Prototype β is an improved version of prototype α, despite remaining working in analogical mode. Both prototypes are capable of producing a CAD representation of the limb via appropriated graphical sheets and were conceived to work purely by mechanical means. The first results were encouraging as they were able to achieve a great decrease concerning the degree of uncertainty of measurements when compared to traditional methods that are very inaccurate and outdated. For instance, it's not unusual to see these archaic methods in action by making use of ordinary home kind measure-tapes for exploring the limb's shape. Although prototype β improved the readings, it still required someone to input the plotted points (i.e. those marked in disk shape graphical sheets) to an academic CAD software called OrtoCAD. This task is performed by manual typing which is time consuming and carries very limited reliability. Furthermore, the number of coordinates obtained from the purely mechanical system is limited to sub-divisions of the graphical sheet (it records a point every 10 degrees with a resolution of one millimeter). These drawbacks were overcome by designing the second release of prototype β in which it was developed an electronic variation of the reading table components now capable of performing an automatic reading (i.e. no human intervention in digital mode). An interface software (i.e. drive) was built to facilitate data transfer. Much better results were obtained meaning less degree of uncertainty (it records a point every 2 degrees with a resolution of 1/10 mm). Additionally, it was proposed an algorithm to convert the CAD geometry, used by OrtoCAD, to an appropriate format and enabling the use of rapid prototyping equipment aiming future automation of the manufacturing process of prosthetic sockets. Devido aos avanços no processo de fabricação de próteses ortopédicas, a necessidade de uma melhor qualidade técnica na leitura da forma (i.e., com menos incertezas) da parte residual dos amputados tornou-se um desafio. Para superar esses problemas é necessário ser capaz de obter informações precisas da geometria do membro e, consequentemente, melhorar os processos de fabricação de próteses e cartuchos transfemurais e transtibiais. O ponto-chave para esta tarefa é personalizar essas leituras tentando ser o mais fiel possível ao verdadeiro perfil de cada paciente. Dentro deste contexto, duas versões (α e β) de um protótipo de um scanner 3D mecânico para ler forma residual de membros com base em técnicas de engenharia reversa foram concebidas. Protótipo β é uma versão melhorada do protótipo α, apesar de ainda trabalhar em modo analógico. Ambos os protótipos são capazes de produzir uma representação CAD do membro através de apropriada planilha gráfica e foram concebidos para funcionar exclusivamente através de meios mecânicos. Os primeiros resultados foram encorajadores, uma vez que foram capazes de conseguir uma grande redução em relação ao grau de incerteza das medições quando comparadas com as dos métodos tradicionais, que são muito imprecisas e desatualizadas. Por exemplo, não é incomum ver estes métodos arcaicos sendo usados utilizando fitas métricas caseiras para medir a forma da perna do paciente. Embora o protótipo β tenha melhorado as leituras, ainda é necessário alguém para introduzir os pontos plotados (i.e., aqueles marcados na planilha em formato de disco gráfico) para um software acadêmico CAD chamado OrtoCAD. Esta tarefa é realizada por digitação manual, que é morosa e tem confiabilidade limitada. Além disso, o número de coordenadas obtidas a partir do sistema puramente mecânico é limitado às subdivisões do disco gráfico (ele grava um ponto a cada 10 graus com uma resolução de um milímetro). Estes inconvenientes foram resolvidos na concepção da segunda versão do protótipo β, na qual foi desenvolvida uma adaptação eletrônica, tornando-o capaz de realizar uma leitura automática (i.e., sem intervenção humana no modo digital). Um software de interface (i.e., driver), foi desenvolvido para facilitar a transferência de dados. Resultados muito melhores foram obtidos significando menor grau de incerteza (ele registra um ponto a cada 2 graus com uma resolução de 1/10 mm). Além disso, foi proposto um algoritmo para converter a geometria CAD, utilizada pelo OrtoCAD, para um formato adequado e que permita a utilização de equipamento de prototipagem rápida destinado a uma futura automação do processo de fabricação dos cartuchos de próteses. 2014-12-17T14:57:49Z 2009-09-17 2014-12-17T14:57:49Z 2009-02-20 masterThesis LACERDA, Ivan Max Freire de. Adaptação eletrônica de um leitor mecânico de coto, investigação e desenvolvimento de interface CAD. 2009. 97 f. Dissertação (Mestrado em Tecnologia de Materiais; Projetos Mecânicos; Termociências) - Universidade Federal do Rio Grande do Norte, Natal, 2009. https://repositorio.ufrn.br/jspui/handle/123456789/15564 por Acesso Aberto application/pdf application/pdf Universidade Federal do Rio Grande do Norte BR UFRN Programa de Pós-Graduação em Engenharia Mecânica Tecnologia de Materiais; Projetos Mecânicos; Termociências