Técnica de controle adaptativo robusto aplicada a filtros ativos de potência e paralelo
The Methods for compensation of harmonic currents and voltages have been widely used since these methods allow to reduce to acceptable levels the harmonic distortion in the voltages or currents in a power system, and also compensate reactive. The reduction of harmonics and reactive contributes to th...
Na minha lista:
Autor principal: | |
---|---|
Outros Autores: | |
Formato: | Dissertação |
Idioma: | por |
Publicado em: |
Universidade Federal do Rio Grande do Norte
|
Assuntos: | |
Endereço do item: | https://repositorio.ufrn.br/jspui/handle/123456789/15318 |
Tags: |
Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
|
id |
ri-123456789-15318 |
---|---|
record_format |
dspace |
institution |
Repositório Institucional |
collection |
RI - UFRN |
language |
por |
topic |
Filtro Ativo de Potência Controle Adaptativo Robustez Sistema com Estrutura Variável e Posicionamento de Pólo Active Power Filter Adaptive Control Robustness Variable Structure Systems and Pole Placement CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA |
spellingShingle |
Filtro Ativo de Potência Controle Adaptativo Robustez Sistema com Estrutura Variável e Posicionamento de Pólo Active Power Filter Adaptive Control Robustness Variable Structure Systems and Pole Placement CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA Braz, érico Cadineli Técnica de controle adaptativo robusto aplicada a filtros ativos de potência e paralelo |
description |
The Methods for compensation of harmonic currents and voltages have been widely used since these methods allow to reduce to acceptable levels the harmonic distortion in the voltages or currents in a power system, and also compensate reactive. The reduction of harmonics and reactive contributes to the reduction of losses in transmission lines and electrical machinery, increasing the power factor, reduce the occurrence of overvoltage and overcurrent. The active power filter is the most efficient method for compensation of harmonic currents and voltages. The active power filter is necessary to use current and voltage controllers loop. Conventionally, the current and voltage control loop of active filter has been done by proportional controllers integrative. This work, investigated the use of a robust adaptive control technique on the shunt
active power filter current and voltage control loop to increase robustness and improve the performance of active filter to compensate for harmonics. The proposed control scheme
is based on a combination of techniques for adaptive control pole placement and variable structure. The advantages of the proposed method over conventional ones are: lower total
harmonic distortion, more flexibility, adaptability and robustness to the system. Moreover, the proposed control scheme improves the performance and improves the transient of
active filter. The validation of the proposed technique was verified initially by a simulation program implemented in C++ language and then experimental results were obtained using
a prototype three-phase active filter of 1 kVA |
author2 |
Ribeiro, Ricardo Lúcio de Araújo |
author_facet |
Ribeiro, Ricardo Lúcio de Araújo Braz, érico Cadineli |
format |
masterThesis |
author |
Braz, érico Cadineli |
author_sort |
Braz, érico Cadineli |
title |
Técnica de controle adaptativo robusto aplicada a filtros ativos de potência e paralelo |
title_short |
Técnica de controle adaptativo robusto aplicada a filtros ativos de potência e paralelo |
title_full |
Técnica de controle adaptativo robusto aplicada a filtros ativos de potência e paralelo |
title_fullStr |
Técnica de controle adaptativo robusto aplicada a filtros ativos de potência e paralelo |
title_full_unstemmed |
Técnica de controle adaptativo robusto aplicada a filtros ativos de potência e paralelo |
title_sort |
técnica de controle adaptativo robusto aplicada a filtros ativos de potência e paralelo |
publisher |
Universidade Federal do Rio Grande do Norte |
publishDate |
2014 |
url |
https://repositorio.ufrn.br/jspui/handle/123456789/15318 |
work_keys_str_mv |
AT brazericocadineli tecnicadecontroleadaptativorobustoaplicadaafiltrosativosdepotenciaeparalelo |
_version_ |
1773962686137106432 |
spelling |
ri-123456789-153182017-11-02T11:40:15Z Técnica de controle adaptativo robusto aplicada a filtros ativos de potência e paralelo Braz, érico Cadineli Ribeiro, Ricardo Lúcio de Araújo http://lattes.cnpq.br/9382571991103772 http://lattes.cnpq.br/6628177274865696 Freitas, Isaac Soares de http://lattes.cnpq.br/7545625055421975 Martins, Allan de Medeiros http://lattes.cnpq.br/4402694969508077 Salazar, Andrés Ortiz http://lattes.cnpq.br/7865065553087432 Filtro Ativo de Potência Controle Adaptativo Robustez Sistema com Estrutura Variável e Posicionamento de Pólo Active Power Filter Adaptive Control Robustness Variable Structure Systems and Pole Placement CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA The Methods for compensation of harmonic currents and voltages have been widely used since these methods allow to reduce to acceptable levels the harmonic distortion in the voltages or currents in a power system, and also compensate reactive. The reduction of harmonics and reactive contributes to the reduction of losses in transmission lines and electrical machinery, increasing the power factor, reduce the occurrence of overvoltage and overcurrent. The active power filter is the most efficient method for compensation of harmonic currents and voltages. The active power filter is necessary to use current and voltage controllers loop. Conventionally, the current and voltage control loop of active filter has been done by proportional controllers integrative. This work, investigated the use of a robust adaptive control technique on the shunt active power filter current and voltage control loop to increase robustness and improve the performance of active filter to compensate for harmonics. The proposed control scheme is based on a combination of techniques for adaptive control pole placement and variable structure. The advantages of the proposed method over conventional ones are: lower total harmonic distortion, more flexibility, adaptability and robustness to the system. Moreover, the proposed control scheme improves the performance and improves the transient of active filter. The validation of the proposed technique was verified initially by a simulation program implemented in C++ language and then experimental results were obtained using a prototype three-phase active filter of 1 kVA Os métodos para compensação de correntes e tensões harmônicas vêm sendo bastante utilizados, visto que esses métodos permitem reduzir a níveis aceitáveis as distorções harmônicas nas tensões ou correntes em um sistema elétrico de potência, e ainda, compensar reativos. A redução de harmônicas e reativos contribuem para: a diminuição das perdas nas linhas de transmissão e nas máquinas elétricas, o aumento do fator de potência e a redução de ocorrências de sobretensões e sobrecorrentes. O filtro ativo de potência é o método mais eficiente para compensação de correntes e tensões harmônicas. No filtro ativo de potência é necessária a utilização de controladores para as malhas de corrente e tensão. Convencionalmente, o controle dessas malhas tem sido feito por controladores proporcionais integrativos. Neste trabalho, é investigado o uso de uma técnica de controle adaptativo robusto nas malha de corrente e tensão, do filtro ativo de potência em paralelo trifásico, para aumentar a robustez e melhorar o desempenho desse filtro ativo na compensação de harmônicos. A técnica de controle proposta é baseada na combinação das técnicas de controle adaptativo por posicionamento de pólos e de estrutura variável. As vantagens do método proposto sobre os convencionais são: menor taxa de distorção harmônica, maior flexibilidade, capacidade de adaptação e robustez para o sistema. Além disso, a técnica de controle proposta aumenta o desempenho e melhora o transitório do filtro ativo. A validação da técnica proposta foi verificada inicialmente através de um programa de simulação implementado em linguagem C ++ e em seguida foram obtidos resultados experimentais usando um protótipo de um filtro ativo trifásico de 1 kVA 2014-12-17T14:55:43Z 2010-10-08 2014-12-17T14:55:43Z 2010-03-26 masterThesis BRAZ, érico Cadineli. Técnica de controle adaptativo robusto aplicada a filtros ativos de potência e paralelo. 2010. 106 f. Dissertação (Mestrado em Automação e Sistemas; Engenharia de Computação; Telecomunicações) - Universidade Federal do Rio Grande do Norte, Natal, 2010. https://repositorio.ufrn.br/jspui/handle/123456789/15318 por Acesso Aberto application/pdf application/pdf Universidade Federal do Rio Grande do Norte BR UFRN Programa de Pós-Graduação em Engenharia Elétrica Automação e Sistemas; Engenharia de Computação; Telecomunicações |