Avaliação do desempenho de uma cortina de estacas espaçadas, atirantada, em areia

It is presented the analysis of a retaining wall designed for the basement of a residential building, located in Natal/RN, which consists in a spaced pile wall, anchored by tiebacks, in sand. This structure was instrumented in order to measure the wall s horizontal movements and the load distributio...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Autor principal: Santos, Fabiana Alves dos
Outros Autores: Costa, Yuri Daniel Jatobá
Formato: Dissertação
Idioma:por
Publicado em: Universidade Federal do Rio Grande do Norte
Assuntos:
Endereço do item:https://repositorio.ufrn.br/jspui/handle/123456789/14859
Tags: Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
id ri-123456789-14859
record_format dspace
institution Repositório Institucional
collection RI - UFRN
language por
topic Estrutura de contenção. Instrumentação. Tirantes
Retaining wall. Instrumentation. Anchors
CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
spellingShingle Estrutura de contenção. Instrumentação. Tirantes
Retaining wall. Instrumentation. Anchors
CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
Santos, Fabiana Alves dos
Avaliação do desempenho de uma cortina de estacas espaçadas, atirantada, em areia
description It is presented the analysis of a retaining wall designed for the basement of a residential building, located in Natal/RN, which consists in a spaced pile wall, anchored by tiebacks, in sand. This structure was instrumented in order to measure the wall s horizontal movements and the load distribution throughout the anchor fixed length. The horizontal movements were measured with an inclinometer, and the loads in the anchors were measured with strain gages, installed in three places throughout the anchor fixed length. Measurements for displacement were done right after the implementation of each stage of the building and right after the conclusion of the building, and the measurements for loads in the anchors were done during the performance test, at the moment of the locking off and, also, right after the conclusion of the building. From the data of displacement were obtained velocity and acceleration data of wall. It was found that the time elapsed on braced installation was decisive in the magnitude of the displacements. The maximum horizontal displacement of wall ranged between 0,18 and 0,66% of the final depth of excavation. The loads in the anchors strongly reduced to approximately half the anchor fixed length, followed an exponential distribution. Furthermore, it was found that there was a loss of load in the anchors over time, reaching 50% loss in one of them
author2 Costa, Yuri Daniel Jatobá
author_facet Costa, Yuri Daniel Jatobá
Santos, Fabiana Alves dos
format masterThesis
author Santos, Fabiana Alves dos
author_sort Santos, Fabiana Alves dos
title Avaliação do desempenho de uma cortina de estacas espaçadas, atirantada, em areia
title_short Avaliação do desempenho de uma cortina de estacas espaçadas, atirantada, em areia
title_full Avaliação do desempenho de uma cortina de estacas espaçadas, atirantada, em areia
title_fullStr Avaliação do desempenho de uma cortina de estacas espaçadas, atirantada, em areia
title_full_unstemmed Avaliação do desempenho de uma cortina de estacas espaçadas, atirantada, em areia
title_sort avaliação do desempenho de uma cortina de estacas espaçadas, atirantada, em areia
publisher Universidade Federal do Rio Grande do Norte
publishDate 2014
url https://repositorio.ufrn.br/jspui/handle/123456789/14859
work_keys_str_mv AT santosfabianaalvesdos avaliacaododesempenhodeumacortinadeestacasespacadasatirantadaemareia
AT santosfabianaalvesdos performanceofaspacedpileswallanchoredbytiebacksinsand
_version_ 1773966440646311936
spelling ri-123456789-148592017-11-02T04:03:12Z Avaliação do desempenho de uma cortina de estacas espaçadas, atirantada, em areia PERFORMANCE OF A SPACED PILES WALL, ANCHORED BY TIEBACKS, IN SAND Santos, Fabiana Alves dos Costa, Yuri Daniel Jatobá http://lattes.cnpq.br/3826575172035095 http://lattes.cnpq.br/6737841388506901 Costa, Carina Maia Lins http://lattes.cnpq.br/6483888857335060 Cunha, Renato http://lattes.cnpq.br/4531085012970834 Estrutura de contenção. Instrumentação. Tirantes Retaining wall. Instrumentation. Anchors CNPQ::ENGENHARIAS::ENGENHARIA CIVIL It is presented the analysis of a retaining wall designed for the basement of a residential building, located in Natal/RN, which consists in a spaced pile wall, anchored by tiebacks, in sand. This structure was instrumented in order to measure the wall s horizontal movements and the load distribution throughout the anchor fixed length. The horizontal movements were measured with an inclinometer, and the loads in the anchors were measured with strain gages, installed in three places throughout the anchor fixed length. Measurements for displacement were done right after the implementation of each stage of the building and right after the conclusion of the building, and the measurements for loads in the anchors were done during the performance test, at the moment of the locking off and, also, right after the conclusion of the building. From the data of displacement were obtained velocity and acceleration data of wall. It was found that the time elapsed on braced installation was decisive in the magnitude of the displacements. The maximum horizontal displacement of wall ranged between 0,18 and 0,66% of the final depth of excavation. The loads in the anchors strongly reduced to approximately half the anchor fixed length, followed an exponential distribution. Furthermore, it was found that there was a loss of load in the anchors over time, reaching 50% loss in one of them Coordenação de Aperfeiçoamento de Pessoal de Nível Superior O presente trabalho apresenta um estudo sobre uma estrutura de contenção projetada para construção do subsolo de um edifício residencial multifamiliar, localizado na cidade de Natal/RN, que consiste em uma cortina de estacas escavadas ancorada por tirantes, em areia. Essa estrutura foi instrumentada a fim de se medirem os deslocamentos horizontais da cortina e a distribuição de cargas ao longo do trecho ancorado dos tirantes. Os deslocamentos horizontais foram medidos através de inclinômetro, e as cargas nos tirantes foram obtidas com uso de extensômetros elétricos de resistência instalados em três pontos ao longo do trecho ancorado. As medições de deslocamento foram feitas após cada etapa de execução da cortina e após a conclusão da obra, enquanto as medições de carga nos tirantes foram feitas durante os ensaios de recebimento, no momento da incorporação e também após a conclusão da obra. A partir dos dados de deslocamento foram obtidos dados de velocidade e aceleração da cortina. Constatou-se que o tempo gasto na instalação do escoramento foi decisivo na magnitude dos deslocamentos. O deslocamento horizontal máximo final da cortina variou entre 0,18 e 0,66% da profundidade final de escavação. As cargas nos tirantes sofrem uma redução muito acentuada até aproximadamente a metade do trecho ancorado, seguindo uma distribuição exponencial. Além disso, constatou-se que houve perda de carga nos tirantes ao longo do tempo, chegando a 50% de perda em um deles 2014-12-17T14:48:18Z 2014-11-18 2014-12-17T14:48:18Z 2013-12-16 masterThesis SANTOS, Fabiana Alves dos. PERFORMANCE OF A SPACED PILES WALL, ANCHORED BY TIEBACKS, IN SAND. 2013. 167 f. Dissertação (Mestrado em MECÂNICA DAS ESTRUTURAS, ESTRUTURAS DE CONCRETO E ALVENARIA E MATERIAIS E PROCESSOS CONSTRUTIVOS) - Universidade Federal do Rio Grande do Norte, Natal, 2013. https://repositorio.ufrn.br/jspui/handle/123456789/14859 por Acesso Aberto application/pdf application/pdf Universidade Federal do Rio Grande do Norte BR UFRN Programa de Pós-Graduação em Engenharia Civil MECÂNICA DAS ESTRUTURAS, ESTRUTURAS DE CONCRETO E ALVENARIA E MATERIAIS E PROCESSOS CONSTRUTIVOS