OBJECTIVE: Evaluating the kit-Bh performance in carrying out of breast biopsies. METHODS: They were randomly selected a sample of 30 patients with breast cancer undergoing mastectomy, based on the results of a pilot study from February 2008 to April 2010. They were excluded women with had not pal...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Autor principal: Souza, Eliel de
Outros Autores: http://lattes.cnpq.br/9777545117488122
Formato: Dissertação
Idioma:por
Publicado em: Universidade Federal do Rio Grande do Norte
Assuntos:
Endereço do item:https://repositorio.ufrn.br/jspui/handle/123456789/13326
Tags: Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
id ri-123456789-13326
record_format dspace
institution Repositório Institucional
collection RI - UFRN
language por
topic Câncer de mama
Biopsia por agulha
Câncer da mama
Câncer mamário
Neoplasias mamárias
Tumores da mama
Breast cancer
Needle Biopsy
Breast neoplasies
Breast
Tumours
Mammary cancer
CNPQ::CIENCIAS DA SAUDE
spellingShingle Câncer de mama
Biopsia por agulha
Câncer da mama
Câncer mamário
Neoplasias mamárias
Tumores da mama
Breast cancer
Needle Biopsy
Breast neoplasies
Breast
Tumours
Mammary cancer
CNPQ::CIENCIAS DA SAUDE
Souza, Eliel de
Abordagem inicial de lesões mamárias por biopsia helicóide: estudo experimental
description OBJECTIVE: Evaluating the kit-Bh performance in carrying out of breast biopsies. METHODS: They were randomly selected a sample of 30 patients with breast cancer undergoing mastectomy, based on the results of a pilot study from February 2008 to April 2010. They were excluded women with had not palpable, stone-hard consistency tumors, previous surgical manipulation or that contains liquid. Using the helicoid biopsy Kit (kit Bh) and an equipment Core biopsy with cannula and needle and 14 gauge respectively, it was collected a fragment of sound equipment in the area and in tumors in each specimen, totaling 120 fragments for histological study. For data analysis, it was defined a 95% confidence level and used the SPSS-13 version, the Kappa index and the parametric Student t test. RESULTS: Mean age of patients was 51.6 years (± 11.1 years). The infiltrating ductal carcinoma showed a higher incidence, 26 cases (86.7%). The Core biopsy had a sensitivity of 93.3%, specificity of 100% and accuracy 96.7%, while the helicoid biopsy had a sensitivity of 96.7%, specificity of 100% and accuracy 98.3%. By comparing the histology of tumors and the fragments of biopsies, there was high degree of agreement in diagnoses (kappa of 0.93 with p <0.05) CONCLUSION: Both devices provided the histological diagnosis of lesions with high accuracy. Results of this study showed that the helicoid biopsy is a reliable alternative in 22 the preoperative diagnosis of breast lesions. Further studies in vivo better will define the role of Kit Bh in the diagnosis of these lesions
author2 http://lattes.cnpq.br/9777545117488122
author_facet http://lattes.cnpq.br/9777545117488122
Souza, Eliel de
format masterThesis
author Souza, Eliel de
author_sort Souza, Eliel de
title Abordagem inicial de lesões mamárias por biopsia helicóide: estudo experimental
title_short Abordagem inicial de lesões mamárias por biopsia helicóide: estudo experimental
title_full Abordagem inicial de lesões mamárias por biopsia helicóide: estudo experimental
title_fullStr Abordagem inicial de lesões mamárias por biopsia helicóide: estudo experimental
title_full_unstemmed Abordagem inicial de lesões mamárias por biopsia helicóide: estudo experimental
title_sort abordagem inicial de lesões mamárias por biopsia helicóide: estudo experimental
publisher Universidade Federal do Rio Grande do Norte
publishDate 2014
url https://repositorio.ufrn.br/jspui/handle/123456789/13326
work_keys_str_mv AT souzaelielde abordageminicialdelesoesmamariasporbiopsiahelicoideestudoexperimental
_version_ 1773967012856332288
spelling ri-123456789-133262019-05-26T05:18:58Z Abordagem inicial de lesões mamárias por biopsia helicóide: estudo experimental Souza, Eliel de http://lattes.cnpq.br/9777545117488122 http://lattes.cnpq.br/7869140767244263 Pinheiro, Luiz Gonzaga Porto http://lattes.cnpq.br/4121910252334757 Oliveira, Ana Katherine da Silveira Gonçalves de http://lattes.cnpq.br/3436756337251449 Câncer de mama Biopsia por agulha Câncer da mama Câncer mamário Neoplasias mamárias Tumores da mama Breast cancer Needle Biopsy Breast neoplasies Breast Tumours Mammary cancer CNPQ::CIENCIAS DA SAUDE OBJECTIVE: Evaluating the kit-Bh performance in carrying out of breast biopsies. METHODS: They were randomly selected a sample of 30 patients with breast cancer undergoing mastectomy, based on the results of a pilot study from February 2008 to April 2010. They were excluded women with had not palpable, stone-hard consistency tumors, previous surgical manipulation or that contains liquid. Using the helicoid biopsy Kit (kit Bh) and an equipment Core biopsy with cannula and needle and 14 gauge respectively, it was collected a fragment of sound equipment in the area and in tumors in each specimen, totaling 120 fragments for histological study. For data analysis, it was defined a 95% confidence level and used the SPSS-13 version, the Kappa index and the parametric Student t test. RESULTS: Mean age of patients was 51.6 years (± 11.1 years). The infiltrating ductal carcinoma showed a higher incidence, 26 cases (86.7%). The Core biopsy had a sensitivity of 93.3%, specificity of 100% and accuracy 96.7%, while the helicoid biopsy had a sensitivity of 96.7%, specificity of 100% and accuracy 98.3%. By comparing the histology of tumors and the fragments of biopsies, there was high degree of agreement in diagnoses (kappa of 0.93 with p <0.05) CONCLUSION: Both devices provided the histological diagnosis of lesions with high accuracy. Results of this study showed that the helicoid biopsy is a reliable alternative in 22 the preoperative diagnosis of breast lesions. Further studies in vivo better will define the role of Kit Bh in the diagnosis of these lesions OBJETIVO: avaliar o desempenho do Kit Bh na realização de biopsias mamárias. MÉTODOS: de fevereiro de 2008 a abril de 2010, com base nos resultados de um estudo piloto, selecionou-se aleatoriamente uma amostra composta de 30 pacientes portadoras de câncer de mama submetidas a mastectomia. Excluíram-se as mulheres portadoras de tumor que tivesse consistência pétrea, não palpável, com manipulação cirúrgica prévia ou que contivesse líquido. Utilizando-se o Kit de biopsia helicóide ( Kit Bh ) e um equipamentos de Core biopsy com cânula e agulha de 14 gauge respectivamente, coletou-se um fragmento por equipamento em área sã e nos tumores, em cada peça cirúrgica, totalizando 120 fragmentos para estudo histológico. Para a análise dos dados definiu-se um nível de confiança de 95% e utilizou-se o software SPSS-versão 13, o índice de concordância Kappa e o teste paramétrico t de Student. RESULTADOS: a média das idades das pacientes foi de 51,6 anos (± 11,1 anos). O Carcinoma ductal infiltrante apresentou maior incidência, 26 casos (86,7%). A Core biopsy apresentou sensibilidade de 93,3%, especificidade de 100% e acurácia de 96,7%, enquanto a Biopsia helicóide teve sensibilidade de 96,7%, especificidade de 100% e acurácia de 98,3%. Na comparação entre a histologia dos tumores e dos fragmentos de biopsias houve alto grau de concordância nos diagnósticos ( Kappa igual a 0,93 com p<0,05) CONCLUSÕES: ambos os equipamentos proporcionaram o diagnóstico histológico das lesões com alta acurácia.Os resultados deste estudo demonstraram que a biopsia helicóide é uma alternativa confiável no diagnostico pré-operatório de lesões mamárias. Estudos mais aprofundados in vivo, definirão melhor o papel do Kit Bh no diagnóstico dessas lesões 2014-12-17T14:13:50Z 2011-05-13 2014-12-17T14:13:50Z 2010-10-17 masterThesis SOUZA, Eliel de. Abordagem inicial de lesões mamárias por biopsia helicóide: estudo experimental. 2010. 112 f. Dissertação (Mestrado em Ciências da Saúde) - Universidade Federal do Rio Grande do Norte, Natal, 2010. https://repositorio.ufrn.br/jspui/handle/123456789/13326 por Acesso Aberto application/pdf application/pdf Universidade Federal do Rio Grande do Norte BR UFRN Programa de Pós-Graduação em Ciências da Saúde Ciências da Saúde